INSTALLATION GUIDE FOR RA-5200
RA-5200 QI
Copyright - refer to title page
Page 54
ENU Status : 1-0-0
These signals are defined as “TTL/CMOS level”, for RRU, the following voltage are valid as EXT_ALM
signals:
Voltage as applied to EXT Alarm pin
Alarm condition as seen by TB-2100
0V to 1.5V
Alarm recognized
3.5V to 5V
No Alarm recognized
3.5.9 MOU SHELF INTERNAL CONNECTION
Information in this section is provided for trained personnel, it is expected the MOU shelf is pre-
configured and tested prior to shipment, and access to the rear of the MOU shelf is not normally
required.
The rear of the MOU shelf is protected by a screwed down back-cover, with the back-cover removed,
the backplane and RF connections exposed. Operating the equipment without the MOU back-cover
fitted is not recommended.
RF Connection between RFU and FOU Units
The fibre below presents the MOU fully equipped with two Double Channel FOUs. The FOU ports
labelled “RX” and “TX” are jumpered to the respective ports labelled “RX” on RFU_UL unit and “TX”
on RFU_DL unit. A total of eight SMA-SMA jumpers exist.