ENU Status : 1-0-0
Shown below is the equipping rule of the MOU shelf.
Solution and SIU equipping
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
4x RRU Solution
2
2
3x RRU Solution
1
2
3x RRU Solution
2
1
2x RRU Solution
2
Blank
2x RRU Solution
1
1
1x RRU Solution
1
RFU_
UL
RFU_
DL
CBU
MCU
PSU
Table 1: MOU shelf equipping rule
•
‘1’ denotes Single Channel FOU (with or without Integrated WDM capability)
•
‘2’ denotes Dual Channel FOU (either with or without Integrated WDM capability).
•
“Blank” denotes position for “Blanking off plate” this slot may be interchanged with Single
Channel FOU
•
“RRU_UL” and ‘RFU_DL” by design is equipped in slot 3 and 4.
•
CBU will be equipped up to customer’s requirement of direct connecting with BTS(s).
•
MCU by design is equipped in Slot 6, PSU by design is equipped in slot 7