19
P/N: 10001609 (REV AB) 627NH
December 2014
MONITOR PARAMETERS
PARAMETER CODE
NAME
FUNCTION
UNITS
MONITOR
U01.01
Frequency Reference
Frequency Reference
Hz
U01.02
Output Frequency
Inverter Output Frequency
Hz
U01.03
Output Current
Inverter Output current
A
U01.04
Control method
Displays the value of A01.02
—
U01.05
Motor Speed
Motor Speed (OLV only)
—
U01.06
Output Voltage
Inverter Output Voltage (Reference)
V
U01.07
DC Bus Voltage
DC Bus Voltage (Measured)
V
U01.08
Output Power
Inverter Output Power (Calculated)
HP
U01.09
Motor Torque
Motor Torque (OLV only)
%
U01.10
Input Terminal
Status Input Terminal Status
—
U01.10
U01.11
Output Terminal Status
Output Terminal Status
—
U01.12
Inverter Control Status
Operation Status
—
U01.11
U01.12