ULTRASONIC HUMIDIFIER NUC-8
APPLIANCE OPERATION
2
Position the humidifier on a hard and stable surface.
Do not position the humidifier on a carpet, lining, parquet floor or surfaces which could be damaged under
the influence of water or moisture.
TANK FILLING
1. Make sure the appliance is unplugged,
2. Remove the nozzle
(5)
from the tank
(3)
3. Take hold of the handle
(4)
and take the tank
(3)
off the base of the appliance
(2)
.
4. Turn the tank, unscrew the cap (fig. 2) and fill the tank with water.
Fix the cap turning it tight.
5. Place the tank
(3)
on the base
(2)
.
6.
Insert the the nozzle
(5)
into opening of the tank
(3)
OPERATION
Every change of the settings is confirmed by a beep.
STANDBY MODE
Connect the device to the mains and turn on the switch (6). The device will display the current humidity.
The humidifier is switched off with the switch (6).
DELAYED START
This function allows the user to set the time, after which the humidifier will automatically start. The function can
only be activated when the device is turned on and in the standby mode. Press „B” – the icon will be
displayed. Set the time with „C” and „D”. Only full hours in the 1-24 range can be selected. The device will show
the lapse of full hours.
Press „B” to switch the humidifier to the standby mode.
BASIC OPERATION
Press „A” use „C” and „D” to set the humidification rate. The device is equipped with a six-step regulation of the
humidity level. The number of illuminated segments indicates the changes. Press „A” once again to switch the
humidifier to the standby mode.
HUMIDITY LEVEL
This function allows the user to set the humidity level in the 15-95% range in steps of 5%. The humidifier deactivates
when the current humidity exceeds the set level and activates when the current relative humidity is lower than
the set value by at least 2%.
This function can only be activated when the device is in the basic operation mode by pressing „B”
GB
fig. 01
1
2
3
4
5
6
E
GENERAL DESCRIPTION
TECHNICAL DATA
1. Control panel
2. Base
3. Water tank
4. Handle for carrying water tank
5. Nozlle
6. On/off switch
- power: 30W
- supply voltage: 230V ~ 50Hz
- capacity 5.2l
- output 300 30ml/h
- appliance output designed
for the room 15-20m
2
- operation time with full water tank ~ 16 hours
INSTRUCTION MANUAL