COLTRI HEAVY DUTY MCH-22 SILENT Use And Maintenance Manual Download Page 9

MU-HEAVYDUTY-0419

HEAVY DUTY

9

 - 60

ENGLISH

customer in full; in any event the warranty is rendered null and void if the 

compressor is tampered with or if work is carried out on it by

personnel who have not been authorised by AEROTECNICA COLTRI SpA.

A compressor that has been acknowledged as faulty on account of flaws 

in design, workmanship or used materials shall be repaired or replaced 

free of charge by AEROTECNICA COLTRI SpA at its plant in Desenzano del 

Garda (BRESCIA); costs regarding transport, delivery of spare parts and any 

materials subject to wear shall be met by the customer.

Should warranty-covered work need to be carried out on the customer’s 

premises, travel and accommodation costs for personnel sent by 

AEROTECNICA COLTRI SpA. shall be met by the customer.

The act of taking delivery of machines and/or faulty components or 

the sending of technicians to assess the presumed defects and/or flaws 

reported by the customer does not in itself imply acknowledgement that 

the defect is covered by warranty.

Repairs and/or replacements made by AEROTECNICA COLTRI SpA during 

the warranty period do not in any way prolong the latter itself.

Acknowledgement that a defect is covered by warranty does not in 

itself mean that AEROTECNICA COLTRI SpA is in any way liable to award 

compensation.

AEROTECNICA COLTRI SpA cannot be held liable for any other direct or 

indirect damages imputable to compressor defects and flaws (loss of 

production or earnings etc.) except in cases where serious negligence is 

demonstrated.

WARNING: Maintenance and repairs must only be carried out 

using original spare parts.

AEROTECNICA COLTRI SpA cannot be held liable for any 

damages caused by failure to observe this rule.

The compressor is guaranteed as per the contractual 

agreements made at the time of sale.

Failure to observe the regulations and instructions for use 

contained in this manual shall render the warranty null and 

void.

1.6

ASSISTANCE

1.7

RESPONSIBILITY

AEROTECNICA COLTRI SpA technicians are at your disposal for all routine/

unscheduled maintenance work.

Please forward your request for assistance to AEROTECNICA COLTRI SpA by 

sending a fax or e-mail to:

Fax. +39 030 9910283

[email protected]

AEROTECNICA COLTRI SpA considers itself exonerated from any 

responsibility or obligation regarding injury or damage caused by:

-  failure to observe the instructions contained in this manual that concern 

the running, use and maintenance of the compressor;

-  violent actions or incorrect manoeuvres during use or maintenance of 

the compressor;

- modifications made to the compressor without prior written 

authorisation from AEROTECNICA COLTRI SpA;

-  incidents beyond the scope of routine, proper use of the compressor.

In any case, should the user impute the incident to a defect of the 

compressor, he/she must demonstrate that the damage has been a major 

and direct consequence of this “defect”.

ESPAÑOL

a cargo del cliente; en cualquier caso la garantía vence automáticamente 

caso que el compresor haya sufrido intervenciones por parte de técnicos 

no autorizados por AEROTECNICA COLTRI SpA.

El compresor que haya sido reconocido como defectuoso por defectos 

de proyección, fabricación o del material, será reparado o sustituido 

gratuitamente por AEROTECNICA COLTRI SpA en su establecimiento de 

Desenzano del Garda (BRESCIA); corren a cargo exclusivo del cliente los 

gastos de transporte, el envío de piezas de recambio y de posible material 

de consumo.

Caso que resulte necesaria una intervención en garantía en la sede del 

cliente, son a cargo de este último los gastos de viaje y dietas del personal 

enviado por AEROTECNICA COLTRI SpA.

El recibimiento de las máquinas y/o de posibles componentes defectuosos 

o los posibles traslados, para la comprobación de defectos señalados por el 

cliente no comportará, en ningún caso, ningún reconocimiento implícito 

por lo que respecta a la operatividad de la garantía.

Reparaciones y/o sustituciones efectuadas por AEROTECNICA COLTRI SpA, 

durante el periodo de garantía, no prolongan la duración de la misma.

El reconocimiento de la garantía no comporta ninguna responsabilidad de 

resarcimiento por cuenta de AEROTECNICA COLTRI SpA.

Por lo que respecta a posibles daños a personas y cosas, así como cualquier 

otro daño directo o indirecto (fallo en la producción o pérdida de beneficios, 

etc.), que pueda imputarse a defectos del compresor, AEROTECNICA COLTRI 

SpA no asume ninguna responsabilidad, exceptuando aquellos casos en los 

que se demuestre una culpa grave a su cargo.

ATENCIÓN: Para las operaciones de mantenimiento o 

reparaciones utilice siempre exclusivamente piezas de 

recambio originales. AEROTECNICA COLTRI SpA declina toda 

responsabilidad por daños provocados al respetar las normas 

arriba indicadas.

El compresor está garantizado según los acuerdos contractuales 

estipulados al momento de la venta.

Sin embargo, la garantía vence caso que no se respeten las 

normas e instrucciones de uso previstas por el presente manual.

1.6

ASISTENCIA

1.7

RESPONSABILIDAD

Los técnicos de AEROTECNICA COLTRI SpA se encuentran a su disposición 

para cualquier intervención de mantenimiento ordinario y extraordinario.

La solicitud de intervención debe dirigirse a AEROTECNICA COLTRI SpA 

enviando un fax o un e-mail a los siguientes números:

Fax. +39 030 9910283

[email protected]

AEROTECNICA COLTRI SpA no se asume ninguna responsabilidad ni 

obligación por cualquier incidente a personas o cosas, provocados por:

-  no observar las instrucciones indicadas en el presente manual por lo que 

se refiere a la conducción, el uso y el mantenimiento del compresor;

-  acciones violentas o maniobras erróneas en el uso y el mantenimiento 

del compresor;

-  modificaciones aportadas al compresor sin previa autorización escrita de 

AEROTECNICA COLTRI SpA;

-  acciones distintas al uso normal y correcto del compresor.

En cualquier caso, si el usuario imputa el incidente a un defecto del 

compresor, deberá demostrar que el daño provocado ha sido una 

consecuencia principal y directa de dicho “defecto”.

Summary of Contents for HEAVY DUTY MCH-22 SILENT

Page 1: ...R PURE BREATHING AIR AND TECHNICAL GASES COMPRESSORE AD ALTA PRESSIONE PER ARIA RESPIRABILE E GAS TECNICI HEAVY DUTY LINE MCH 22 30 36 45 OPEN MCH 22 30 36 45 SILENT USE AND MAINTENANCE MANUAL English...

Page 2: ...resentative Aerotecnica Coltri SpA Claudio Coltri Translation of the original declaration ESPA OL DECLARACI N DE CONFORMIDAD CE En virtud del Anexo II punto A de la Directiva 2006 42 CE Anexo IV de la...

Page 3: ...MPORTANT BEFORE USING THE COMPRESSOR READ THIS MANUAL CAREFULLY WARNING The compressors are delivered without the refill hoses or filtration cartridge these items are supplied inside the packaging ESP...

Page 4: ...ones preliminares coloque el compresor en el lugar preelegido V ase Cap 5 conecte si es necesario la extensi n para la toma de aire V ase Cap 5 3 2 compruebe el nivel del aceite V ase Cap 7 8 comproba...

Page 5: ...NDICE 1 DESCRIPCI N GENERAL 7 1 1 Informaci n preliminar 7 1 2 Requisitos de formaci n de los operadores 7 1 3 Avisos para el uso 7 1 4 Premisa 8 1 5 Garant as 8 1 6 Asistencia 9 1 7 Responsabilidad...

Page 6: ...s 58 ESPA OL 6 USO DEL COMPRESOR 33 6 1 Controles a realizar antes de la primera puesta en servicio 33 6 1 1 Introducci n del cartucho filtrante 33 6 1 2 Comprobaci n de la conexi n de las fases el ct...

Page 7: ...ls and their meaning They highlight essential information ESPA OL AVISO Hace referencia a integraciones o sugerencias para un uso correcto del compresor ATENCI N Hace referencia a situaciones de pelig...

Page 8: ...s de servicio descritas en el presente manual constituyen parte integrante del suministro del compresor Dichas normas est n destinadas al operador formado expresamente para conducir este tipo de compr...

Page 9: ...a cargo del cliente en cualquier caso la garant a vence autom ticamente caso que el compresor haya sufrido intervenciones por parte de t cnicos no autorizados por AEROTECNICA COLTRI SpA El compresor q...

Page 10: ...que posean el certificado correspondiente y no supere la presi n de ejercicio indicada sobre las mismas Aspire aire no sea viciado ni est contaminado Utilice el compresor en ambientes sin polvo y en l...

Page 11: ...fectamente el funcionamiento del aparato y sus mandos y haber le do y comprendido toda la informaci n t cnica contenida en el presente manual Se proh be utilizar el compresor en condiciones o para uso...

Page 12: ...ical gases Compatible process gases Nitrogen Helium Nitrox 40 max O2 Each compressor has an identification label attached to its frame Thread Tightening torque values 6 and 4 bolt torque sequence Max...

Page 13: ...ar usar o llevar a cabo cualquier mantenimiento sobre el compresor Debe guardarse atentamente en un lugar conocido por el usuario del compresor los responsables los encargados del transporte instalaci...

Page 14: ...e 3 2 GENERAL PRECAUTIONS ESPA OL La directiva m quinas da las siguientes definiciones ZONAPELIGROSA cualquierzonadentroy ocercadeunam quinaenlaquela presencia de una persona constituya un riesgo para...

Page 15: ...seguridad Toda operaci n de instalaci n mantenimiento ordinario y extraordinario debe llevarse a cabo con el compresor parado y sin alimentaci n el ctrica Tras haber efectuado la limpieza del compreso...

Page 16: ...Se proh be la modificaci n o sustituci n de partes del compresor no expresamente autorizadas por AEROTECNICA COLTRI Elusodeaccesorios herramientas materialesdeconsumoopartes derecambiodistintosalasrec...

Page 17: ...ing fan 8 Danger of direct contact with operator if hose breaks during bottle refill ESPA OL PELIGRO Enalgunaszonasdelcompresorexistenriesgosresiduales quenohasidoposibleeliminarenfasedeproyecci nnili...

Page 18: ...cate maximum working pressure lower than that indicated on compressor 3 3 1 Safety info labels description ESPA OL 3 3 UBICACI N DE LAS PLACAS DE SEGURIDAD No utilice el compresor sin haber le do ante...

Page 19: ...miento de todas las funciones del compresor y a los riesgos consecuentes b Leer atentamente el manual de uso y mantenimiento antes de poner en funcionamiento el compresor c Aviso de peligro por presen...

Page 20: ...ESPA OL Etiqueta del sentido de rotaci n del ventilador de refrigeraci n En la primera puesta en funcionamiento de la m quina verifique que el sentido de rotaci n del ventilador de refrigeraci n corre...

Page 21: ...mantenimiento como falta de aceite limpieza insuficiente ineficiencia del circuito del aire comprimido da os de los tubos flexibles apretado de los tubos tornillos etc Realice esmeradamente los trabaj...

Page 22: ...clean 3 5 5 Warning signs ESPA OL El mantenimiento ordinario prescrito en el presente manual debe ser llevado a cabo s lo por personal autorizado y con pr ctica Para el mantenimiento o revisi n de co...

Page 23: ...l pistones cilindros 4 1 2 V lvulas 4 1 3 V lvulas de seguridad 4 1 CARACTER STICAS T CNICAS El monobloque est realizado con aleaci n de aluminio la brida con los cojinetes de rodillos que sujetan el...

Page 24: ...n 37 Belt 38 Anti vibration device 39 Refill hose 40 Refill valves 41 Condensate separator ESPA OL 4 2 NOMENCLATURA 1 Armaz n 2 Panel de mando 3 Pulsador de encendido 4 Pulsador de paro 5 Pulsador de...

Page 25: ...x1530 790x1052x1823 1 790x1052x1917 2 790x1052x1530 790x1052x1823 1 790x1052x1917 2 790x1052x1530 790x1052x1823 1 790x1052x1917 2 inches 31 1x41 4x60 2 31 1x41 4x71 8 1 31 1x41 4x75 5 2 31 1x41 4x60 2...

Page 26: ...air filter 25 Safety valve 26 Pressure gauge 4th stage 27 Pressure maintaining valve 28 Pressure switch 29 Flex hoses ESPA OL 4 4 CIRCUITO DE PRESI N 1 Filtro de aspiraci n 2 V lvula de aspiraci n 1...

Page 27: ...sieve air filter 26 Safety valve 27 Pressure gauge 4th stage 28 Pressure maintaining valve 29 Pressure switch 30 Flex hoses ESPA OL 1 Filtro de aspiraci n 2 V lvula de aspiraci n 1 estadio 3 V lvula d...

Page 28: ...ntrol board Voltage command circuit Voltage signal circuit Total power control board Total current equipment Higher current equipment Power interruption Degree of protection 14 00009_R1 3P T VAC 230VA...

Page 29: ...the utmost care when lifting transferring and positioning the compressor ESPA OL El compresor est introducido en una caja de cart n colocada sobre un europallet para que pueda ser desplazada y transp...

Page 30: ...3 1 Positioning 5 3 INSTALLATION ESPA OL Coloque el compresor en el lugar previsto y compruebe que est nivelado Para las medidas del compresor consulte el p rrafo 4 3 Tabla de las caracter sticas t cn...

Page 31: ...armful gases or exhaust fumes ESPA OL 5 3 2 Conexi n de la extensi n para la toma de aire Caso que el compresor se coloque en un lugar que no re na las caracter sticasdeventilaci nindicadasenelp rrafo...

Page 32: ...s power are compatible with those of the compressor ESPA OL 5 3 3 Conexi n el ctrica El compresor se entrega equipado con cable el ctrico y enchufe trif sico 32A 3P T Para la conexi n el ctrica es suf...

Page 33: ...n time for cooling reported in the table Engine power Kw Use minutes Cooling minutes ESPA OL El operador debe comprobar que el compresor est equipado con manual de uso y mantenimiento En caso de reven...

Page 34: ...e refill flex hoses are in good condition ESPA OL Realice una inspecci n externa del compresor juntas tubos componentes neum ticos etc y controle si existen p rdidas de aceite Si es necesario sustituy...

Page 35: ...xcessive pressure the valve setting is made at the time of testing the compressor The safety valve are pre adjusted to 6 2 3 Checking the safety valves IMPORTANT The safety valves must be replaced eve...

Page 36: ...ESPA OL 6 3 PANEL DE MANDO ATENCI N Se proh be modificar los par metros de presi n sin autorizaci n de AEROTECNICA COLTRI so pena el vencimiento de la garant a caso que el compresor a n est cubierto...

Page 37: ...matically The compressor can reach a maximum pressure of 232 300 330 420 bar 3300 4300 4700 6000 PSI ESPA OL compresor con el fin de efectuar el mantenimiento previsto 10 Man metro de la presi n del c...

Page 38: ...icated ESPA OL Para la puesta en marcha del compresor presione el pulsador de puesta en marcha b Para apagar el compresor presione el pulsador c AVISO Estas operaciones deben ser realizadas por person...

Page 39: ...ise disconnect the bottle coupling ESPA OL Compruebe las condiciones de las botellas a llenar Prueba de ensayo del rgano autorizado punzonado y o certificado Control visual externo Compruebe las condi...

Page 40: ...plate of the dryer voltage frequency air pressure air temperature ambient temperature etc ESPA OL 6 6 REFRIGERADOR SECADOR OPCIONAL AVISO Para cualquier intervenci n de uso y mantenimiento no especif...

Page 41: ...high ambient temperature etc The treatment of the compressed air may be improper ESPA OL Panel de control a Interruptor ON OFF arranque apagado b Term metro anal gico El term metro utilizando la pant...

Page 42: ...Espere unos minutos compruebe que el term metro indica la temperatura de ejercicio correcta y que la condensaci n se descarga regularmente Alimente el compresor de aire Apagado Apague el compresor de...

Page 43: ...ause the filtering cartridge will not be totally saturated If no led is turned on it means that the PRESEC is missing electric tension or the electrical system is faulty SATURATION FILTER VALUES Light...

Page 44: ...adas exclusivamente por el servicio de Asistencia Clientes de AEROTECNICA COLTRI o por personal calificado 7 MANTENIMIENTO PELIGRO No efect e operaciones de mantenimiento si acaba de apagar el compres...

Page 45: ...lve Condensate discharge change sintered filter Coolers tube ESPA OL Son aquellas operaciones de reparaci n y o sustituci n de partes mec nicas de uno o varios componentes del compresor que por norma...

Page 46: ...5 TROUBLESHOOTING ESPA OL Problema Causa Soluci n El motor el ctrico no arranca Falta una fase Controle los fusibles y lo condensador La velocidad de rotaci n y la capacidad disminuyen La potencia de...

Page 47: ...ter change interval should be reduced to every 50 hours ESPA OL Despu s de la prima puesta en servicio es necesario sustituir el filtro de aspiraci n despu s de las primeras 50 horas de uso del compre...

Page 48: ...he filtration cartridge are classified as special waste they must be disposed of in compliance with the anti pollution standards in force ESPA OL 7 7 FILTRO PURIFICADOR La sustituci n del cartucho fil...

Page 49: ...r sieve Active carbon Molecular sieve Hopkalite Active carbon Molecular sieve ESPA OL Sustituci n de lo cartuchos filtrante d1 d2 descargue completamente el compresor eliminando el aire comprimido de...

Page 50: ...essure gauge must mark a pressure higher than zero ESPA OL Despu s de la primera puesta en servicio es necesario proceder a la sustituci n del aceite lubricante despu s de las primeras 50 horas de uso...

Page 51: ...aceite El nivel del aceite debe controlarse cada 50 horas de funcionamiento del compresor El nivel del aceite debe hallarse entre el nivel m nimo y m ximo sobre el indicador del nivel del aceite h Se...

Page 52: ...las correas de transmisi n debe efectuarse cada 500 horas de uso del compresor o con una periodicidad anual Comprobaci n del tensado de las correas de transmisi n Para comprobar el tensado de las corr...

Page 53: ...staff in serious danger and could cause serious damage or injury ESPA OL 7 10 DESCARGA DE LA CONDENSACI N La descarga de la condensaci n se efect a autom ticamente cada 7 minutos El pulsador amarillo...

Page 54: ...USTITUCI N DE LOS LATIGUILLOS Para volver a reemplazar los latiguillos de recarga de las botellas siga las indicaciones descritas a continuaci n desconecte los latiguillos de recarga de las botellas d...

Page 55: ...ves must be replaced every 5 years or 3000 hours ESPA OL 7 12 V LVULAS DE SEGURIDAD Caso que no utilice el compresor gu rdelo en un ambiente seco protegido contra los agentes atmosf ricos y a una temp...

Page 56: ...proceda con la puesta fuera de servicio o el desguace del mismo Dicha operaci n debe efectuarse siguiendo las normativas vigentes 9 DESGUACE PUESTA FUERA DE SERVICIO 9 1 ELIMINACI N DE LOS DESECHOS AT...

Page 57: ...RO DE LOS MANTENIMIENTOS 10 1 SERVICIO DE ASISTENCIA 10 2 INTERVENCIONESDEMANTENIMIENTOPROGRAMADO 10 3 USO DEL COMPRESOR EN CONDICIONES DIF CILES 10 4 EL CUSTOMER CARE CENTRE El cliente tambi n recibe...

Page 58: ...SISTANCE SERVICE STAMP TECHNICIAN S SIGNATURE DATE TYPE OF WORK AND NOTES ASSISTANCE SERVICE STAMP TECHNICIAN S SIGNATURE DATE ESPA OL 10 5 BOLET N DE MANTENIMIENTO PROGRAMADO TIPO DE INTERVENCI N Y A...

Page 59: ......

Page 60: ...AEROTECNICA COLTRI Spa Via Colli Storici 177 25015 DESENZANO DEL GARDA BS ITALY Tel 39 030 9910301 Fax 39 030 9910283 www coltri com MU HEAVYDUTY 0419...