8.1. Installation of the exhauster fan for regeneration of exhaust air
When plastics are being dried that release harmful gases during the drying process, care must be
taken that the regeneration exhaust air is disposed of in an environmentally sound way. At the
same time the throughput of the regeneration blower must not be altered. It should be noted when
assembling a disposal system (e.g. an exhauster system) that the regeneration exhaust air is very
humid. Thus condensation may form, which must not under any circumstances return to the dryer.
8.2. Connection of Return Air Cooler (Optional)
F
A return air cooler must be employed if the return air temperature is hig-
her than +65 °C (149 °F).
The return air cooler can be connected to a coolant circuit or the water mains network.
Observe the water flow with connection to water mains network. The coolant circuit must be di-
mensioned acccordingly.
Remove the side panel of the dryer.
Connect the coolant intake line and coolant return line to the return air cooler.
Obeserve the flow direction of the coolant through the return air cooler.
Check the connections for leaks.
Mount the side panel.
64.10-0260GB05
06/03
CTT 250
Assembly instructions 8-2
Summary of Contents for CTT 250
Page 80: ...Accessories Spare parts list Drying Hoppers TT 25 TT 6400 GB01 01 03 Colortronic GmbH...
Page 83: ...GB01 01 03 TT 25 TT 6400 4 15 D 9 10 11 12 13 14 PT 100 1 2 3 4 5 6 7 17 16 8 18 PT 100 A C B...
Page 86: ...Accessories Entering values on the OP 7 17 Colortronic GmbH 02 01GB...
Page 92: ...Accessories Flap control with Fuzzy Logic Colortronic GmbH 10 00GB...