46-
Reference: Softkeys
Scoreboard
This menu
controls the parameters that affect modular fixed digit scoreboards (CTS LED and
light-reflective).
Option
1
Self Test
checks all scoreboard digit segments by running a test pattern on the
scoreboard. You can stop the test pattern display by pressing any key.
Option
2
Define Module(s)
Function:
Allows you to send one module’s data to a different module. Carefully read the
Scoreboard section in chapter 2 before attempting to redefine any scoreboard modules. In the
Swimming software all scoreboard module logical addresses default to the physical addresses.
For example, the physical switch setting for the scoreboard module displaying data for lane 1 is
01, so the logical address is also 01. If you want the lane 1 (01) scoreboard module to display
line 10's data set its logical address in this setup to 0A. On the module definition window, as
shown in Figure 4-G, the physical addresses appear on the left, the redefined logical addresses on
the right.
Operation:
Press
2
to display or change scoreboard module definitions, press the
Up
or
Down
softkey until the arrow points at the desired physical address as shown in Figure 4-H, then press
1
and type the two-digit logical address in the prompt box with the numeric keypad (and with the
softkey menu if a letter is required, as in 0A). Press
2
to display module definitions on the
scoreboard. Press
2
again to clear definitions on the scoreboard.
Figure 4-H Scoreboard Module Definition Window
Note:
Scoreboard module numbers and sample displays appear in Chapter 2 and Appendix
E.