Unitary Products Group
15
345095-CTG-B-0907
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HIGH CFM
COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
HC8B036F1
INDOOR COIL MODEL NO.
FC/MC62D + MV12D
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
1148
1248
1348
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
38.4 39.7 40.2 43.7 47.8 39.4 40.6 40.8 44.4 48.5 40.5 41.5 41.3 45.2 49.1
S.C.
38.4 35.1 30.0 29.8 24.1 39.4 37.0 31.1 30.9 24.9 40.5 38.8 32.2 32.0 25.7
K.W.
1.7 1.7 1.7 1.8 1.8 1.7 1.7 1.7 1.8 1.8 1.7 1.8 1.8 1.8 1.8
75
T.C.
37.0 38.0 38.2 41.8 45.7 38.0 38.7 38.8 42.4 46.3 39.0 39.4 39.3 43.0 46.9
S.C.
37.0 34.5 29.3 29.1 23.4 38.0 36.1 30.4 30.2 24.1 39.0 37.7 31.5 31.3 24.8
K.W.
2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.1
85
T.C.
35.6 36.2 36.3 39.9 43.6 36.5 36.8 36.8 40.4 44.1 37.4 37.4 37.3 40.9 44.6
S.C.
35.6 33.9 28.6 28.4 22.6 36.5 35.2 29.7 29.4 23.3 37.4 36.5 30.8 30.5 24.0
K.W.
2.2 2.2 2.2 2.2 2.3 2.2 2.2 2.2 2.2 2.3 2.2 2.2 2.2 2.3 2.3
95
T.C.
34.2 34.5 34.3 37.9 41.5 35.0 34.9 34.8 38.3 41.9 35.8 35.3 35.3 38.7 42.4
S.C.
34.2 33.3 27.8 27.7 21.9 35.0 34.3 28.9 28.7 22.5 35.8 35.3 30.0 29.7 23.2
K.W.
2.4 2.4 2.4 2.5 2.5 2.4 2.4 2.4 2.5 2.5 2.5 2.4 2.4 2.5 2.5
105
T.C.
32.2 32.4 31.9 35.3 38.7 33.0 32.9 32.3 35.7 39.1 33.8 33.5 32.7 36.0 39.5
S.C.
32.2 31.6 26.9 26.7 20.9 33.0 32.5 28.0 27.8 21.5 33.8 33.5 29.1 28.8 22.2
K.W.
2.7 2.7 2.7 2.8 2.8 2.8 2.8 2.7 2.8 2.8 2.8 2.8 2.8 2.8 2.8
115
T.C.
30.3 30.4 29.6 32.7 36.0 31.1 31.0 29.9 33.1 36.4 31.9 31.6 30.3 33.4 36.7
S.C.
30.3 30.0 26.0 25.8 19.9 31.1 30.8 27.1 26.9 20.6 31.9 31.6 28.2 28.0 21.2
K.W.
3.0 3.0 3.0 3.1 3.1 3.1 3.1 3.0 3.1 3.1 3.1 3.1 3.0 3.1 3.1
125
T.C.
28.4 28.4 27.2 30.1 33.3 29.2 29.1 27.5 30.5 33.6 29.9 29.8 27.8 30.8 33.9
S.C.
28.4 28.4 25.0 24.9 19.0 29.2 29.1 26.2 26.0 19.6 29.9 29.8 27.3 27.1 20.3
K.W.
3.3 3.3 3.3 3.4 3.4 3.4 3.4 3.3 3.4 3.4 3.4 3.4 3.3 3.4 3.4
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
AV36
-
0.98 0.97 0.97
AV/SV48
-
1.01 1.04 0.98
MV16C
FC/MC43C
0.97 0.93 0.95
MV16C
FC/MC48C
0.98 0.95 0.96
MV12D
FC/MC48D
0.97 0.91 0.96
MV12D
FC/MC60D
0.97 0.93 0.97
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
(F,L)C8(C,V)*B16
FC/MC/PC43B
0.98 0.95 1.00
(F,L)C8(C,V)*C16
FC/MC/PC43C
0.98 0.96 1.01
(F,L)C8(C,V)*C20
FC/MC/PC43C
0.98 0.95 1.01
FC9(C,V)*B12
FC/MC/PC43B
0.97 0.94 0.97
FC9(C,V)*C16
FC/MC/PC43C
0.97 0.95 1.00
FC9(C,V)*C20
FC/MC/PC43C
0.98 0.95 1.00
(F,L)C8(C,V)*C16
FC/MC/PC48C
0.99 0.96 1.02
(F,L)C8(C,V)*C20
FC/MC/PC48C
0.98 0.96 1.02
FC9(C,V)*C16
FC/MC/PC48C
0.98 0.96 1.01
FC9(C,V)*C20
FC/MC/PC48C
0.98 0.96 1.12
FC9(C,V)*D20
FC/MC/PC48D
0.99 0.97 1.01
(F,L)C8(C,V)*C16
FC/PC60C
0.98 0.97 1.01
(F,L)C8(C,V)*C20
FC/PC60C
0.98 0.97 1.01
FC9(C,V)*C16
FC/PC60C
0.97 0.96 1.00
FC9(C,V)*C20
FC/PC60C
0.97 0.96 0.99
FC9(C,V)*D20
FC/MC/PC60D
0.98 0.97 1.00
(F,L)C8(C,V)*C20
FC/MC62D
0.99 0.98 1.03
FC9(C,V)*C20
FC/MC62D
0.99 0.98 1.01
FC9(C,V)*D20
FC/MC62D
1.00 0.98 1.02
(F,L)C8(C,V)*C16
HC42
0.98 0.95 1.01
(F,L)C8(C,V)*C20
HC42
0.97 0.94 1.01
FC9(C,V)*C16
HC42
0.98 0.95 1.00
FC9(C,V)*C20
HC42
0.98 0.95 1.00