Cole Parmer IPSW 100 User Manual Download Page 6

Page 2 

 

 

 
 

1.0

 

INTRODUCTION

 

 

• 

IPSW scales provide accurate, fast and versatile general purpose type weighing 
scales with parts counting, percentage weighing and check-weighing functions.  

 
• 

IPSW scales have LED’s next to the display to indicate when a weight is below 
the low limit, in between the limits or above the high limit. These can work in 
conjunction with an audible alarm for check weighing as well as the display 
showing LOW, OK and HI. 

 
• 

IPSW scales can be supplied with an optional RS-232 bi-directional interface and 
real time clock (RTC). In order to maintain the IP washdown rating this feature is 
installed before leaving the factory. 

 
• 

IPSW scales have a sealed keypad with color coded membrane switches, a large 
easy to read liquid crystal display (LCD) and a green backlight.   

 

 

 

Summary of Contents for IPSW 100

Page 1: ...IPSW Series Washdown Scales User Manual xxxxxxxxxx Revision A June 2017 ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ... ANIMAL DYNAMIC WEIGHING 12 7 0 USER PARAMETERS 14 CHECK WEIGHING PARAMETERS 14 PERCENT WEIGHING and ANIMAL WEIGHING 15 RS 232 PARAMETERS 15 SCALE PARAMETERS 16 8 0 BATTERY OPERATION 18 9 0 RS 232 INTERFACE 18 INPUT COMMANDS FORMAT 21 10 0 RELAY INTERFACE 21 11 0 CALIBRATION 22 12 0 SERVICE PARAMETERS 23 USING 1000 TO ENTER THE SERVICE PARAMETERS 23 USING THE SERVICE PARAMETERS 24 13 0 ERROR CODES...

Page 6: ...e limits or above the high limit These can work in conjunction with an audible alarm for check weighing as well as the display showing LOW OK and HI IPSW scales can be supplied with an optional RS 232 bi directional interface and real time clock RTC In order to maintain the IP washdown rating this feature is installed before leaving the factory IPSW scales have a sealed keypad with color coded mem...

Page 7: ...01kg 0 01lb 0 005kg 0 01lb 0 005kg 0 02lb 0 01kg Repeatability Std Dev 0 004lb 0 002kg 0 004lb 0 002kg 0 02lb 0 01kg 0 02lb 0 01kg 0 04lb 0 02kg Linearity 0 004lb 0 002kg 0 004lb 0 002kg 0 02lb 0 01kg 0 02lb 0 01kg 0 04lb 0 02kg Pan size w x d 9 8 x9 8 250x250mm 11 8 x15 7 300x400mm 11 8 x15 7 300x400mm 15 7 x19 7 400x500mm 17 7 x23 6 450x600mm Units of Measure g kg lb lb oz Newton oz ...

Page 8: ...t or near air conditioning vents Avoid unsuitable tables The table or floor must be rigid and not vibrate Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not place near vibrating machinery Avoid high humidity that might cause condensation Avoid direct contact with water Do not spray or immerse the scale in water Avoid air movemen...

Page 9: ...vided Adjust the viewing angle of the Indicator to the ideal position and tighten two the locking handles Level the scale by adjusting the adjusting feet until the bubble is in the center of the level indicator If the scale rocks re adjust the feet NOTE Use of a food safe grease is recommended on the threaded part of the feet to keep them turning freely Attach the power input connector to the indi...

Page 10: ...r S1 in section 7 4 of this manual A secondary function is to move the active flashing digit to the left when setting values for Parameters Selects the Function parameters of the scale A secondary function C is to act as a clear key when clearing an accumulated total Sends the results to a PC or a Printer using the RS 232 interface It also adds the value to the accumulation memory if the accumulat...

Page 11: ...ction has been enabled A battery bar symbol will show the state of charge of the internal battery 6 0 OPERATION ZEROING THE DISPLAY You can press the 0 T key at any time to set the display to zero This will usually be when the platform is empty When the zero point is obtained the display will show an indicator for zero The scale has an automatic re zeroing function to account for minor drifting or...

Page 12: ...e if another type of product was to be added to the first one Again only the weight that is added after taring will be displayed NOTE The NET indicator will only be ON when the tare weight exceeds 4 2 weighing divisions of the scale capacity When the container is removed a negative value will be shown If the scale was tared just before removing the container this value is the gross weight which in...

Page 13: ... be used leaving the empty container on the scale Place a known number of samples in the container if used The number should match the options for parts counting i e 10 20 50 100 or 200 pieces When the scale is showing weight pressing the Pcs key will start the parts counting function The scale will show P 10 asking for a sample size of 10 parts Change the sample size to the desired quantity by pr...

Page 14: ...ill be active when the corresponding LED is on during check weighing The ZERO relay output will be on when the scale is showing the display is at Zero ACCUMULATED TOTAL The scale can be set to accumulate manually by pressing the Print M Esc key or automatically when a weight is removed from the scale See Section 7 3 for details of setting the Parameter C3 PRM and C4 Aon The accumulation function i...

Page 15: ... T key P1 PCt will be displayed Press 0 T again to enter percent weighing The scale will set the sample mass on the platform as 100 reference weight Remove the sample weight Then any other weight placed on the scale will be displayed as a percentage of the original sample For example if 3500g is placed on the scale and percent weighing is selected the display will show 100 0 Remove the 3500g weigh...

Page 16: ...s FunC 1 press the Func C key again to display Func 2 Press the 0 T key F1 PCt will be displayed Press the Pcs key to advance to the second function P2 Ani Animal weighing Press 0 T to enter animal weighing The scale will change to animal weighing and allow weighing of an unstable animal or sample on the platform To use the Animal Weighing function it is necessary to set the amount of filtering re...

Page 17: ...ghing symbol while a stable weight is determined The time it takes for the stable value will depend upon the setting of the filter parameter in the first step When a stable reading is found the display will show this value and the display will be locked until the 0 T key is pressed The display will show the Hold symbol while the display is locked To weigh a second subject press the 0 T key if nece...

Page 18: ...tion 6 5 for details of using this special weighing mode This group of parameters Set low and high limits for check weighing Enables or disables the check weighing alarm Enables or disables the negative check weighing Press the Func C key then 0 T to access the FunC 1 settings group F1 Lo parameter Press 0 T to enter the settings sub menu and then use the Unit key and Pcs key to select and change ...

Page 19: ...r Parameter section and return to weighing Parameter Description Options Default setting P1 PCt This parameter allows the user to enter the Percent weighing Function See Section 6 7 None Enabled always P2 Ani Enter the Animal Weighing mode of operation See section 6 8 Set the filter value Enabled Always RS 232 PARAMETERS Press 0 T to enter a parameter Use the Unit key and Pcs key to set the values...

Page 20: ...rint automatically Do not accumulate mAn Accumulate and Print only when Print M Esc key pressed If Print M Esc is pressed a second time only print the weight Print when Print M Esc key is pressed Do not accumulate Cont Print continuously Accumulate when Print M Esc key is pressed Print continuously Do not accumulate SCALE PARAMETERS Press 0 T to view the list of parameters Press 0 T to enter a par...

Page 21: ...U EL AU S3 AoF Auto Off Disable or set time increment to turn off scale SLP 0 SLP 1 SLP 5 SLP 10 SLP 0 S4 dt Set Time and Date format and settings Format for date can be changed when the display shows mmddyy ddmmyy or yymmdd by pressing the Pcs key then enter the date Enter the time manually Enter the date format and then the numeric value manually 00 00 00 mm dd yy S5 diS Display all weights or o...

Page 22: ...s of battery charging When the scale is plugged into the mains power the internal battery will be charged If the LED is green the battery has a full charge If it is red the battery is nearly discharged and yellow indicates the battery is being charged 9 0 RS 232 INTERFACE The indicator can be supplied with an optional bi directional RS 232 interface The scale when connected to a printer or compute...

Page 23: ...456 cr lf If ID is zero it is left blank User ID 234567 cr lf cr lf Net Wt 1 234 Kg cr lf Net Wt or Gross Wt cr lf cr lf cr lf cr lf cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf Net Wt 1 234 Kg cr lf Net Wt or Gross Wt Unit Wt 123 g cr lf g for metric and lb for pounds PCS 10 pcs cr lf cr lf cr lf cr lf cr lf cr lf Date 12 09 2006 cr ...

Page 24: ...r unit counted Unit Wt Pds unit Gew Einh Pso Unid Number of items counted Pcs Pcs Stck Piezas Number of weighing added to subtotals No Nb Anzhl Num Total weight and count printed Total Total Gesamt Total Print date Date Date Datum Fecha Print time Time Heure Zeit Hora Scale ID number Scale ID Bal ID Waagen ID Bal ID User ID Number User ID Util ID Nutzer ID Usuario ID ST GROSS 1 234 Kg cr lf ST or ...

Page 25: ... outputs requiring the use of an external power supply for the relays The output to drive external relays is on the circuit board inside the enclosure To gain access you must remove the 6 screws securing the front to the rear of the case Pass the wires for the relays through the grommet on the rear panel The wires will connect to the PCB using the terminal strip P1 ZERO LOW OK HI COM SHIE SEN EXE ...

Page 26: ...efore calibration The display will show either kg or lb to identify the weights expected PROCEDURE Enter the calibration section using Func 4 C8 CAL or using the passcode as described in section 12 0 The display will show unLoAd Remove any weight from platform and when the stable symbol is on press 0 T The display will show Ld then 0000XX which shows the last calibration weight used Place this cal...

Page 27: ...number 1000 using the Unit and Pcs keys and then press 0 T The displays will show the first parameters called F4 Int To select another parameter press the Pcs key to advance through the parameters Press the 0 T key to enter a parameter To exit a parameter press the Print M Esc key The display will show the parameter number and a name When a parameter is entered by pressing the 0 T key the displays...

Page 28: ...f Press the Pcs key to change the value Press 0 T to accept the displayed value Press Print M Esc to return to weighing F7 ADC COUNTS To enter this parameter press the 0 T key when F7 Cnt is shown This parameter allows you to view the A D counts from the internal A D converter This can be an aid to service Press the 0 T key to return to the PARAMETER menu Press the Print M Esc key to return to wei...

Page 29: ... if the current Auto Zero range Press the Pcs key to change the value Press 0 T to accept the displayed value Press Print M Esc to return to weighing Fb FPS User Function Password This parameter set a password to control access to the user functions as described in Section 7 If the password is set to 0000 the control is disable and the user has free access to the functions To enter this parameter ...

Page 30: ...e sure the pan is fitted correctly Indicates the load cell or the electronics may be faulty If the problem persists contact your supplier for assistance Err 7 100 weight out of range Weight value set as 100 for percentage weighing must be greater than 50 weighing divisions of the scale Err 9 Check weigh limits error Shown if the low limit is set higher than the current high limit Reset High limit ...

Page 31: ... B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in your record for ready reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and plac...

Page 32: ...adioactive or corrosive materials negligence faulty installation unauthorized modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual This product may include a rechargeable battery that is designed to be removed and replaced by the user The supplier will provide a replacement battery if the battery manifests a defect in materials o...

Page 33: ... a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense C...