![Cole Parmer IPSW 100 User Manual Download Page 22](http://html1.mh-extra.com/html/cole-parmer/ipsw-100/ipsw-100_user-manual_2635454022.webp)
Page 18
8.0
BATTERY
OPERATION
•
The scale can be operated from the battery if desired. The battery life can be
up to 70 hours depending on the load cells and how the backlight is used.
•
A battery symbol is shown on the display which indicates the current charge of
the battery, 3 bars means fully charged. When just the outline of the battery and
no bars are visible the battery needs to be re charged.
•
To charge the battery, simply plug the adaptor into the mains power, and also
into the input connector on the rear of the Indicator marked DC 12V. The scale
does not need to be turned on.
•
The battery should be charged for 12 hours to reach full capacity.
•
Near the display is an LED to indicate the status of battery charging. When the
scale is plugged into the mains power the internal battery will be charged. If the
LED is green the battery has a full charge. If it is red the battery is nearly
discharged and yellow indicates the battery is being charged.
9.0
RS-232
INTERFACE
The indicator can be supplied with an optional bi-directional RS-232 interface. The scale,
when connected to a printer or computer outputs the weight with the selected weighing unit
through the RS-232 interface.
RS-232 serial interface plug (As viewed from the back of the indicator):
1: Pin GND, Signal Ground
2: Pin RXD, Received Data
3: Pin TXD, Transmitted Data
4: Not connected
The scale can be set to print text in English, French, German or Spanish. See the RS-232
parameters section for details.
RS-232 output of weighing data
ASCII code
600 - 19200 Baud (user selectable, default 9600)
8 data bits
No Parity
1 stop bit
No flow control