P R O G R A M M I N G
!RFID RDAFTWT
Function This
command
initiates
an integrity test following a
WT command. Data is read and undergoes a byte-
by-byte comparison with the initial data. The
comparison occurs before the WT command is
returned as successful or failed.
Explicit Form
!RFID RDAFTWT ON/OFF
Parameters
ON
Byte-by-byte comparison with initial
data is performed.
OFF
No comparison is performed.
Response
No specific response
Command Type
RFID Setup/Debug Command
Example To
Printer:
!RFID RDAFTWT OFF
NOTE:
All CPL-RFID Configuration-Setup Commands
are processed outside the context of a standard CPL
Label-Format (i.e. CPL beginning with a header-line ‘! 0
100 nnn 1’ and ending with ‘END’). Attempts to use
CPL-RFID Configuration-Setup Commands within a
Label-Format result are ignored without indication.
Copyright © 2004, Cognitive.
58