Installing the MVS-8100M
Cognex MVS-8100M Hardware Manual
17
Using Rapid Reset Cameras
Cognex uses the term rapid reset to describe electronic shutter control or trigger shutter
control. Cameras that can be used in rapid reset mode include:
•
Sony XC-55 or XC-55 BB camera
•
Sony XC-ST50 or XC-ES50 camera with switch settings in rapid reset mode
•
Pulnix TM-9701 with CCF video format (MVS-8100M+ only)
To use one of these cameras in rapid reset mode with the 8100M or 8100M+, you must
set a jumper for the camera port to which the camera is attached. Table 4 shows the
jumper settings for each camera port. Jumper locations are found in the following
locations:
•
For the 8100M, Style A, see in Figure 15 on page 34
•
For the 8100M, Style B, see Figure 16 on page 35
•
For the 8100M+, see Figure 17 on page 36
Note
Setting jumpers JP10 through JP13 for rapid reset support disables
the use of a light module on that camera port. You cannot use rapid
reset cameras and light modules on the same 8100M or 8100M+
camera port at the same time. However, each camera port can be
set individually, so you can mix rapid reset cameras with other types.
Installing External I/O Equipment
You can connect the following peripheral equipment to the MVS-8100M:
•
One high-speed optically isolated trigger pulse generator to trigger image
acquisitions on one to four monochrome cameras.
•
One high-speed open collector strobe light to allow 8100-controlled illumination of
the scene under one to four monochrome cameras.
Camera port
Jumper
Cover these pins for
rapid reset support
0
JP13
2-3
1
JP12
2-3
2
JP11
2-3
3
JP10
2-3
Table 4.
Jumper settings for Sony XC-55 support