You can choose between a variety of different S-Mount/M12 (including variable-
focus liquid lens module) and C-Mount lens options to be installed on your
DataMan 300 series reader.
WARNING: Make sure your reader is
unpowered before installing the lens.
2
3
4
1. Connect the reader to the Setup Tool.
2. On the Results Display pane, check the Focus Feedback option and
enable Live Display. For best results, adjust your camera settings to
make sure you have a brightened and high contrast image.
3. Use the
DataMan Focus Target
template, available through the
Windows Start menu or the Setup Tool Help menu, to align the edge
of the reader body to the line marked with the target distance used
in your application.
4. Adjust focus for maximum sharpness. Enhance image quality in the
Setup Tool for better guidance.
Press the rubber lens-locking cone into the reader.
While carefully avoiding rotating the lens, press the rubber lens cone
into the reader until it snaps into place around the nose of the lens.
14 DataMan 300 Quick Reference Guide
DataMan 300 Quick Reference Guide 15
Installing the Lens
Remove lens plug.
1
Installing M12 lens with Manual Focus
Thread the lens into the reader.
Place the reader at the desired working distance from focus target.