Do not stare into beam when adding, removing, or
changing cables. Cognex recommends to unpower the
reader any time you make physical changes to it.
CONNECT YOUR READER
1. Connect the I/O+RS232+24V cable to your reader.
2. For a network connection, connect your reader, through an Ethernet
cable, to your network.
3. Connect the cable to a 24V power supply.
50 DataMan 300 Quick Reference Guide
DataMan 300 Quick Reference Guide 51
DataMan 300 Series Imager Specifications
Specification
DataMan 300 Series Imager
Image Sensor
1/1.8 inch CMOS
Image Sensor Properties
6.9 mm x 5.5 mm (H x V); 5.3 µm square pixels (DataMan
300 and 302), 4.5 µm square pixels (DataMan 303)
Image Resolution (pixels)
• DataMan 300: 800 x 600
• DataMan 302: 1280 x 1024
• DataMan 303: 1600 x 1200
Electronic Shutter Speed
• minimum exposure: 5 µs (DataMan 300 and 302), 12 µs
(DataMan 303)
• maximum exposure: 1000 µs with internal
illumination/100000 µs with external illumination
Image Acquisition at Full
Resolution
• DataMan 300 and 302: up to 60 fps
• DataMan 303: up to 40 fps
Lens Type
• S-Mount 10.3 mm F:5 (with optional liquid lens)
• S-Mount 16 mm F:9
• C-Mount lenses (with limitations, see below)
Limitations to C-Mount lenses:
• The length of the thread may not exceed 5.4 mm.
• The back side of the lens may not exceed beyond the C-Mount threads. Possibly a lens
spacer is required.
•
When using the C-Mount lens cover, lens dimensions including spacer and filters may
not exceed 32 x 42 mm (diameter x length).
To avoid accelerated aging of built-in illumination LEDs, which results in light intensity
degradation, consider the following duty cycle limits above 25°C (77°F):
• at 35°C (95°F): 4% duty cycle, for example, 750 µs exposure and 18493 µs interval
• at 45°C (113°F): 2% duty cycle, for example, 350 µs exposure and 18093 µs interval
or 1000 µs exposure and 50000 µs interval
Installing DataMan Software and
Connecting the Reader
INSTALL DATAMAN SOFTWARE AND CONNECT
1. Check the DataMan Release Notes for a full list of system
requirements.
2. Insert CD-ROM and follow the on-screen prompts until you
successfully completed the DataMan Software installation process.
3. Connect the DataMan 300 Series reader to your PC.
4. Launch the Setup Tool and click
Refresh
.
Detected readers will appear under
COM ports
or
Network
devices
, or both.
5. Select a reader from the list and click
Connect
.