COFFEtek
LTD
31
28/02/2017
Revision 1
VITRO S3
The value 380 is a number corresponding to the temperature setting.
The value (0,0) is the element status.
Press PROG to exit from the TANK STATUS option and access the next Engineer's
Program option.
Set the Credit Lock to 0.
C
HANGE
S
ETTINGS
38.
CHANGE SETTINGS allows alteration of the following machine settings:
There are several submenus, that cover various aspects;
TEMPERATURE SETTINGS
MACHINE SETTINGS
MAINTENANCE SETTINGS
PAYMENT SYSTEM SETTINGS
AUDIT SETTINGS
TIMED EVENT SETTINGS
LIGHTING SETTINGS
Temperature Settings
39.
Settings
Description
DESIRED
TEMP
86°C (0407)
Allows setting of normal operating temperature for the Instant boiler.
TEMP LOW
75°C (0332)
Allows setting of low cut-out point for the Instant boiler.
ECON TEMP
60°C (0230)
Allows setting of the Economy mode the Instant boiler will lower to if set in the
TIMED ACTIVITIES
CUP BOOST
Allows increase/decrease of temperature boost per cup dispense.
RESERVED 1
17
RESERVED 2
30