channel
function
type of control
effect
percentage decimal
12
effects selection
(prism, split
color)
step
no effects
0/16%
0-41
effect 1
17/32%
42-85
effect 2
33/48%
86-125
effect 3
49/65%
126-169
effect 4
66/80%
170-209
effect 5
81/100%
210-255
13
effects rotation
proportional
proportional effect rotation 360°
0/50%
0-128
proportional
continuos effect rotation clockwise with proportional
speed from max to min.
51/74%
129-190
step
effect stop
75%
191
proportional
continuos effect rotation counter-clockwise with
proportional speed from min. to max
76-100%
192-255
14
color wheel
proportional
proportional color wheel rotation 360° from white to
the last color
0/75%
0-191
proportional
continuos color wheel rotation clockwise with
proportional speed from min. to max.
76/100%
192-255
15
cyan
proportional
proportional cyan control from white to cyan
0/100%
0-255
16
magenta
proportional
proportional magenta control from white to magenta
0/100%
0-255
17
Yellow
proportional
proportional yellow control from white to yellow
0/100%
0-255
18
function
step
lamp off
0/45%
0-114
motor reset
46/55%
115-140
lamp on
56/100%
141-255
N.B. function channel has a delay time of 6 second to prevent indesiderate accident.
Note 1: 2 or 4 numbers close to the end limit levels cannot be used as unstable levels