7. Electrical connection
connection between the ballast and the coemar nat mm 1200
ZOOM 15/30°
1) Locate the power cable at the rear of the
coemar nat mm 1200 ZOOM
15/30°
; this is provided with a 6 pin, 16A plug(A).
2) Insert the plug into the socket (B) located on the ballast, ensuring a secure fit.
Close the mechanical stop.
coemar nat mm 1200 ZOOM 15/30°
is supplied with a 3.5m cable for con-
nection between the projector and the ballast. Extension cables are available to
cater for a greater distance between the two, as required.
10m extension cable
coemar
cod. 9204
20m extension cable
coemar
cod. 9204/1
cabling
The mains cable provided is thermally resistant, complying to the most recent inter-
national standards. It meets or exceeds the VDE and IEC norms, IEC 331, IEC 332
3C, CEI 20 35.
NB: In the case of cable replacement, similar cable, with comparable thermal resi-
stant qualities must be used exclusivelly (cable 3x1,5 ø external 10 mm, rated
300/500V, tested to 2KV, operating temperature -40° +180°,
coemar
cod.
CV5309).
mains connection
coemar nat mm 1200 ZOOM 15/30°
can operate at either 208v, 230v, or
240v at 50 or 60Hz (selectable as described in section 4 of this manual).
Prior to connecting the fixture to mains power, ensure that you have the correct
model to suit your mains power.
For connection purposes, ensure your plug is of a suitable rating: 9,5 amps for
model 230 v.
Locate the mains cable on the ballast:
protection
The use of a thermal/magnetic circuit breaker is recommended for each
coemar
nat mm 1200 ZOOM 15/30°
.
A good earth connection is essential for the correct operation of the fixture. Strict
adherance to regulatory norms is strongly recommended.
marrone - brown
blu - blue
giallo/verde - yellow/green
marrone - brown
blu - blue
giallo/verde - yellow/green
marrone - brown
blu - blue
giallo/verde - yellow/green
massa
gr
ound
neutr
o
neutral
fase
phase
Alimentazione
main
50/60 Hz selector
50/60 Hz selector
50/60 Hz selector
function display
menu
+
-
enter
50/60 Hz selector
A
B