25
25
9.7
Error messages
If a malfunction occurs,
LEDko EXT FullSpectrum
has a self-diagnostic system that will
show the error message on the display. The following table will explain in detail the most
common errors. If, despite of suggested intervention, the problem persists, call the
Coemar
Service Center.
9.6
Special functions of the fixture
Storing the DMX signal
To use the fixture without an active DMX console it is possible to store the DMX settings
in two ways:
•
Through the
TEST
menu;
•
Disconnecting the DMX signal when the fixture is on. When the signal is unconnected
the fixtures stores the signal;
Automatic fan standby
To decrease the noise and the power consumption the cooling fan turns off after 10
minutes of fixture inactivity.
Error code
Description
DTER
[Data Error]
Data error
Initial data loading has failed the projector loaded the default
data settings: restart the fixture again, and if the error persists
contact the
Coemar
assistance center.
ADER
[Address Error]
Address error
The projector does not receive all channels of DMX needs to
function properly. Check the DMX address indicated on the
display and the number of channels generated by the mixer
control. We recall in this connection that some controllers do
not generate all the 512 channels.
noal
[No Alarm]
No Alarm
The projector self-diagnostic routine didn’t find any issue.
LEd
[Data Error]
LED error
Auto diagnostic routine found that the LED module may
damaged, contact Coemar assistance for the module
replacement.
IMPORTANT:
To ensure the sensor is giving correct readings,
set the LED to the maximum light output level.