background image

16

16

8

. DMX chart

8.1

 DMX Chart 11, 8, 4, 1 channels

Tabella DMX (11/8/4/1ch ENG)

channel number

standard RGB

type of 

control

effect

decimal percentage

11ch 8ch 4ch 1ch

1

1

-

1

master dimmer

proportional adjust luminous output intensity from 0 to 100%

0 - 255 0% - 100%

2

2

1

-

red

proportional proportional control of the color percentage from 0 to 

100%

0 - 255 0% - 100%

3

3

2

-

green

proportional proportional control of the color percentage from 0 to 

100%

0 - 255 0% - 100%

4

4

3

-

blue

proportional proportional control of the color percentage from 0 to 

100%

0 - 255 0% - 100%

5

5

4

-

white

proportional proportional control of the color white percentage from 0 to

100%

0 - 255 0% - 100%

6

6

-

-

strobe effect

step

no effect

0 - 9 0% - 4%

proportional variable speed strobing effect, from slow to fast

10 - 57 4% - 22%

step

stop strobe

58 - 59 23% - 23%

proportional sequenced pulsed strobe, slow closing, fast opening

(variable speed pulsing, from slow to fast)

60 - 108 24% - 42%

step

stop strobe

109 - 110 43% - 43%

proportional sequenced pulsed strobe, fast closing, slow opening

(variable speed pulsing, from slow to fast)

111 - 159 44% - 62%

step

stop strobe

160 - 161 63% - 63%

proportional colours (variable speed from slow to fast)

162 - 207 64% - 81%

step

stop strobe

208 - 209 82% - 82%

proportional (variable speed from slow to fast)

210 - 255 82% - 100%

7

7

-

-

proportional

0 - 255 0% - 100%

8

8

-

-

special functions

step

park

0 - 9 0% - 4%

no effect

10 - 40 4% - 16%

no effect

41 - 71 16% - 28%

600 Hz

72 - 84 28% - 33%

fan at low-noise speed

85 - 96 33% - 38%

fan at auto speed

97 - 108 38% - 42%

 proportional fan speed control from minimum to maximum

109 - 120 43% - 47%

step

no effect

121 - 133 47% - 52%

LCD display off

134 - 185 53% - 73%

LCD display on

186 - 199 73% - 78%

LED control frequency tuning 1000 Hz

200 - 205 78% - 80%

LED control frequency tuning 3000Hz

206 - 211 81% - 83%

LED control frequency tuning 6000Hz

212 - 217 83% - 85%

LED control frequency tuning 8000Hz

218 - 223 85% - 87%

LED control frequency tuning 10000Hz

224 - 229 88% - 90%

LED control frequency tuning 12000Hz

230 - 235 90% - 92%

LED control frequency tuning 14000Hz

236 - 241 93% - 95%

LED control frequency tuning 16000Hz

242 - 247 95% 97%

LED control frequency tuning 19000Hz

248 - 255 97% - 100%

Summary of Contents for Ledko EXT FullSpectrum

Page 1: ...Version 1 0 instruction manual Provisional EXT FullSpectrum...

Page 2: ...in providing spare parts repairs or in answering any technical enquiries with the utmost speed and accuracy WARNING the security of the fixture is granted only if these instructions are strictly foll...

Page 3: ...s tilt Pag 11 4 4 Optic group framing system and gobos Pag 11 5 Powering up Pag 13 5 1 Operating voltage and frequency Pag 13 5 2 Connection to mains power Pag 13 6 Control signal connections Pag 14 6...

Page 4: ...4 4 11 Maintenance Pag 26 11 1 Firmware update Pag 26 11 2 Periodic cleaning Pag 26 11 3 Periodic controls Pag 26 11 4 Fuses Pag 26 12 F A Q and answers Pag 27...

Page 5: ...inform them you will formally notify them in writing through registered letter Packing list Ensure the packaging contains 1 Reflection LEDko EXT FullSpectrum 1 Instruction manual 2 General informatio...

Page 6: ...under warranty for 12 months from the purchase date against factory defections 2 Damage ought to unskillfulness inappropriate use or lack of suggested maintenance are excluded from the warranty 3 War...

Page 7: ...actor Cos 0 98 Power consumption 180 watt Color temperature RGBW with a perfect color mixing Weight without optic 16kg 30 8lbs Maximum temperature da 10 C a 35 C IP rating IP65 3 Product specification...

Page 8: ...8 8 3 3 Unit s main components A B C D Components description A Yoke with mounting holes B Cooling assembly C Optical holder tube D Locking screw for yoke...

Page 9: ...9 9 3 4 Back panel description Plus Botton Minus Botton DMX Out DMX In Display Menu Botton Enter Botton Power In...

Page 10: ...structure and fixing bolts clamps etc are rated to support the weight of the fixture 4 2 Safety chain When hanging LEDko EXT FullSpectrum it is recommended to use a safety chain as required by curren...

Page 11: ...optical holder tube B pulling it away from the body 3 Loose the thumbscrews C of the two lenses to set them at desired position Turn on the fixture and check if the desired focus and zoom lever are co...

Page 12: ...obo holder 7 Reassemble the projector by pushing the optical holder tube on the optical group and tighten the screws that has been removed at the beginning NB When putting the screws be careful not to...

Page 13: ...Spectrum is equipped with two power connectors one as input and one as output which can be used to feed up to 8 at 230 VAC or 4 90 VAC fixtures The max absorption of LEDko EXT FullSpectrum is reported...

Page 14: ...nductors are not in contact one another or with the metal housing of the connector Pin 1 and housing never must be connected to the power supply unit 6 1 Control signal connection by XLR5 plugs The di...

Page 15: ...t 11 channels a projector thus addressed will respond to commands of channel 1 to 11 from your DMX 512 controller A second unit must be addressed as A012 a third one as A023 and so on The operation mu...

Page 16: ...43 43 proportional sequenced pulsed strobe fast closing slow opening variable speed pulsing from slow to fast 111 159 44 62 step stop strobe 160 161 63 63 proportional colours variable speed from slo...

Page 17: ...GREEN Preset 4 196 255 77 100 11 blue tone step no effect 0 9 0 4 BLUE Preset 1 10 71 4 28 BLUE Preset 2 72 133 28 52 BLUE Preset 3 134 195 53 76 BLUE Preset 4 196 255 77 100 NOTE 1 color macros of c...

Page 18: ...ons of the projector so that it will respond differently to the controller therefore carefully read about the functions described here before carrying out any possible selection 9 2 Rapid count Throug...

Page 19: ...logarithmic and linear exponential as default Test Allows to set manually some different options Dimmer it allows to set the luminous intensity Strobe manually sets the strobe Store stores all the new...

Page 20: ...he password is a sequence of 4 buttons pressed in order Auto it allows to turn off the display after 6 seconds Password Allows to set a keyboard lock after 10 seconds of inactivity The keyboard can be...

Page 21: ...fault of the fixture with exception of DMX address and LED alignment Measures Allows to read all the parameters LED and board temperatures fan level DMX ratio DMX allarms channels value and software v...

Page 22: ...e of the DMX channels received by the fixture on every channel that the fixture occupies on the line Rate Shows the refresh rate of the DMX signal sent by the console Alarm This menu eventually shows...

Page 23: ...s of life of the fixture LED life shows the overall LED module life LED life reset shows the overall LED module life currently installed Note this items can be reset in case of LED module replacement...

Page 24: ...d be considered for the exclusive use of technicians and qualified personnel 9 5 Electronic alignment of the leds The display panel of LEDko EXT FullSpectrum allows the electronic alignment of the LED...

Page 25: ...off after 10 minutes of fixture inactivity Error code Description DTER Data Error Data error Initial data loading has failed the projector loaded the default data settings restart the fixture again a...

Page 26: ...pened with a special lens cleaning solution Cleaning of the unit Use a soft brush or a common vacuum cleaner or a source of compressed air for removing dust For the cleaning of the housing use a soft...

Page 27: ...FullSpectrum is not responding to DMX signal DMX signal may not reach LEDko EXT Inspect the cable connection correct poor connections or inefficient repair or replace damaged cables Check DMX address...

Page 28: ...28 28 User notes...

Page 29: ...center for waste electrical and electronic equipment The treatment and disposal of environmentally friendly helps prevent potential negative environmental and health and promote the reuse and or recy...

Page 30: ...ighting s r l Via Carpenedolo 90 46043 Castiglione delle Stiviere Mantova Italy phone 39 0376 1514412 fax 39 0376 1514380 info coemar com Coemar reserves the right to effect modifications without noti...

Reviews: