If the operating voltage set by
coemar
does not correspond to that is use in your country of operation, or if the projectors are desti-
ned for use in another country, a new operating voltage selection may be made as described below.
Incorrect frequency and voltage selection will detrimentally affect the operation of the projector and immediately void the warranty.
19.1. Selecting an operating voltage on the transformer.
1) Using a Philips-head screwdriver, loosen the screws on the base cover as shown in the diagram below, thus remove the cover to
gain access to the internals of the base of the
iSPOT 575 MB.
2) Locate the transformer in the base.
3) Select a voltage from between 100,115, 208, 230 and 240V
by disconnecting cable n° 5 and moving it to the required vol-
tage. To ensure the correct voltage is selected, refer to the stic-
ker on the transformer.
Cable number 3 should, under no circumstances, be moved
from its current position.
4) If the selected voltage is 115V, replace the 8 Amp T fuse, suita-
ble for 208/230/240 V operation, with one rated at 15 Amps
T (or vica-versa). The fuse is located in the fuseholder in the
base of the projector. Replacement fuses are provided in an
envelope in the original packaging of the fixture alongside this
instruction manual.
5) Make a note on the outside of the base of the
iSPOT 575 MB
of the voltage which you have selected.
6) Replace the base cover and re-affix the screws which were previously removed.
19. Altering the operating voltage
(Reserved for technical staff)
23
English
Summary of Contents for iSPOT 585 MB