preparing the cable
The mains cable provided is thermally resistant, having VDE approval and complying to the most recent international standards, namely IEC
331, IEC 332 3C,CEI 20 35.
NB: In case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable 3x1,5 ø
external 10 mm, rated 300/500V, tested to 2KV, operating temperature -40° +180°,
coemar
cod. CV5309).
mains connection
iSPOT 575 MB
may operate at 100V-115V-208V-230V-240V at 50 or 60Hz (operating voltage should be selected as discussed in
section 5 of this manual). Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly mat-
ches the mains supply available to you. For connection purposes, ensure that your plug is of a suitable rating: : 4.5 amps at 230V,
8 Amps at 115 V. Locate the mains cable which exits the base of the unit and connect as shown below:
protection
The use of a thermal magnetic circuit breaker is recommended for each
iSPOT 575 MB
.
A good earth connection is essential for the correct operation of the fixture. Strict adherence to regulatory norms is strongly recom-
mended.
massa/ground
neutro/neutral
fase/live
marrone - brown
blu - blue
giallo/verde - yellow/green
alimentazione
main
7. Mains connection