9
English
cabling
The mains cable provided is thermally resistant, complying to the most recent international standards. It meets or exceeds VDE and IEC
norms, IEC 331,IEC 332 3C,CEI 20 35.
NB: In case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable 3x1.5
ø external 10 mm, rated 300/500V, tested to 2KV, operating temperature -40° +180°,
coemar
cod. CV5309).
mains connection
The iSpot 575
can operate at voltages from 208V-230V-240V at 50 or 60Hz (operating voltage and frequency can be
selected as described in section 5 of this manual).
Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly matches the mains
supply available to you. For connection purposes, ensure your plug is of a suitable rating of 8 amps.
Locate the mains cable which exits the base of the unit and connect as shown below:
protection
The use of a thermal magnetic circuit breaker is recommended for each
iSpot 575
.
A good earth connection is essential for the correct operation of the fixture. Strict adherence to regulatory norms is strongly
recommended.
massa/ground
neutro/neutral
fase/live
marrone - brown
blu - blue
giallo/verde - yellow/green
alimentazione
main
7. Mains connection