channel
function
type of control
effect
decimal
13
gobo 2 selection
standard (Strd)
step
no gobo
0-20
step
gobo 1
21-42
step
gobo 2
43-64
gobo 3
65-86
step
gobo 4
87-108
step
gobo 5
109-130
step
gobo 6
131-151
proportional
gobo wheel rotate continously, speed from min to max
152-255
NOTE: channel 13 function can be varied selecting gobo standard/special function on the back function display
13
gobo 2 selection
special (SPEc)
step
no gobo (clear)
0-10
proportional
proportional gobo wheel rotation 360° from no gobo to the last
gobo
11-151
proportional
gobo wheel rotate continously, speed from min to max
152-255
14
effects selection
(prism, lens)
step
no effects (clear)
0-83
effect 1
84- 171
effect 2
172-255
15
prism rotation
proportional
proportional fine prism positioning 360°
0-128
proportional
continuos prism rotation clockwise with proportional speed from
max. to min.
129-189
step
prism stop
190-192
proportional
continuos prism rotation counterclockwise with proportional
speed from min. to max.
193-255
16
No effect
NOTE: channel 16 select gobo or iris focal lens when ch 20 is between 171 and 200
16
Focal lens
step
Iris focal lens
0-85
step
Gobo focal lens
86-170
step
Narrow angle
171-255
17
cyan
proportional
proportional cyan control from white to cyan
0-255
18
magenta
proportional
proportional magenta control from white to magenta
0-255
19
Yellow
proportional
proportional yellow control from white to yellow
0-255
20
Lamp ON, motor
Reset, zoom
control mode
step
lamp off
0-10
step
park, no function (idle)
11-29
step
pan/tilt go to sensor
30-100
step
all motor reset (only once)
101-170
step
zoom control free
171-200
step
zoom fast autofocus
201-240
step
progressive zoom autofocus
241-249
step
Lamp ON (progressive zoom autofocus)
250-255
Back panel can modify function channel (inhibit lamp off)
You can use the unit in MODE 2, the CF 7 HEX add one more channel (21)
21
pan/tilt movement
selection
step
standard movement
0-127
step
soft movement
128-255
note 1: 2 or 4 numbers close to the end limit levels cannot be used as unstable levels
note 2: function channel (20) has a delay time of 6 second to prevent accidental activation.
note 3 :on/off lamp mode is not affected unless an opposite value is received
English