background image

 

 

 

     

  

  

USER  MANUAL  

 
 
 

             

 

NPZ336-RGBAW

 

   

 

 

 

 

Summary of Contents for NPZ336-RGBAW

Page 1: ... USER MANUAL NPZ336 RGBAW ...

Page 2: ...instruction 1 outside size picture 2 main function 2 DMX control function 3 Display operation instruction 5 Menu instruction 5 Signal cable connection 10 Trouble shooting 11 Technical specification 13 Please read over this manual before operating the light Index ...

Page 3: ...n a fashion of hydrodynamic form It takes uses high power R G B W A 5 kinds LED It uses power switch performs low weight and consumption stable capability and long life The built in program includes dimmer strobe zooming and so on International standard DMX 512 signal is requested Ø Packing List Ø NPZ336 1 PC Ø DMX Signal Cable 1 PC Ø IP65 Input power cable 1 PC Ø User Manual Ø Warranty Card 2 Saf...

Page 4: ...ture is lower than 45 degree The fixtures maybe mounted in any position provided there is adequate room for ventilation Make sure there are no inflammable and explosive items ornaments in 0 5 meters away Yellow green cabling earthling safety no flicker when the fixture is working on 3 Outside Size Picture 4 Main Function Ø high quality LED low consumption brightness stable capability and long life...

Page 5: ... Channel Channel Value Function CH1 0 255 General Dimming CH2 0 255 Red CH3 0 255 Green CH4 0 255 Blue CH5 0 255 Amber CH6 0 255 White CH7 0 10 Turn off strobe 11 255 Adjust the speed of strobe 1 20Hz CH8 0 255 zoom in zoom out CH9 0 10 Invalid 11 20 WHITE 1 3200K 21 30 WHITE 2 3400K 31 40 WHITE 3 4200K 41 50 WHITE 4 4900K 51 60 WHITE 5 5600K 61 70 WHITE 6 5900K 71 80 WHITE 7 6500K 81 90 WHITE 8 7...

Page 6: ... At least 5S 9 Channels Channel Value Function CH1 0 255 General Dimming CH2 0 255 Red CH3 0 255 Green CH4 0 255 Blue CH5 0 255 Amber CH6 0 255 White CH7 0 10 Turn off the strobe 11 255 Adjust strobe speed 1 20Hz CH8 0 255 zoom in zoom out CH9 0 10 User Dimmer mode set by menu 11 20 Dimmer off 21 30 Dimmer 1 31 40 Dimmer 2 41 50 Dimmer 3 51 60 Dimmer 4 61 254 User Dimmer mode set by menu 255 Light...

Page 7: ... access the menu or return to a previous menu option Ø ENTER select the current menu option Ø UP menu selection or parameter increments Ø DOWN menu selection or parameters decreas 7 Menu Instruction 7 1 Menu MENU ADDR address 001 512 STAT static RED 0 255 GREN 0 255 BLUE 0 255 AMBER 0 255 WHIT 0 255 SHUT STROBE 0 255 ZOOM 0 255 AUTO AT01 RUN AT02 RUN AT03 RUN AT04 RUN AT05 RUN AT06 RUN AT07 RUN AT...

Page 8: ...eter YES NO REST Light fixture reset YES NO SEND Send parameter to other light fixtures YES NO Notes 1 While entering into menu asterisk setting automatically send data out for the mater Other light fixtures can receive the same data and operate synchronously 2 The underline parts are factory defaults 7 2 DMX Adress setting MENUà ADDR address à 001 512 u At Menu ADDR Press ENTER to enter into DMX ...

Page 9: ...speed 0 255 u At Menu AUTO Press ENTER to enter into choosing setting u Press UP DOWN to choose AT01 AT10 SPEED u Press ENTER to operate 7 5 Built in Color temperature Color balance setting MENUà WTST Color balance parameter setting à WT01 à RED à 0 255 GREN à 0 255 BLUE à 0 255 WHIT à 0 255 AMB à 0 255 WT10 à u At Menu WTST Press ENTER to enter into built in color temperature color balance settin...

Page 10: ...TE AMBER output will transform into the corresponding percent output according to the calibrated value 7 7 Channel Setting MENUà CHMD à 11CH 9CH 7CH 5CH u At Menu CHMD press ENTER to enter into channel setting u Press UP DOWN to choose 11CH 9CH 7CH 5CH u Press ENTER to exit and store 7 8 Dimming Setting MENUà DIM à OFF DIM1 DIM2 DIM3 DIM4 u At Menu DIM Press ENTER to enter into dimming setting u P...

Page 11: ...ght fixtures resetting u Press UP DOWN to choose YES u Press ENTER to reset 7 12 Send parameter to other light fixtures MENUà SEND à YES NO u At Menu SEND Press ENTER to enter into sending parameter to other light fixtures u Press UP DOWN to choose YES u Press ENTER to send Notes 1 Cut off the connection with the controller before sending parameter 2 It is unavailable to send ADDR CAL The other li...

Page 12: ...e XRL is one end connect to the male plug and the other connect to the female As bellow pin 1 ground pin 2 negative signal pin 3 positive signal Noted In order to avoid failures and interference signal transmission we connect a resistance120Ω 1 4W at the end of the DMX connecting as below Ø The Conversion between 3pin and 5 pin XLR If the output cable of DMX512 controller is the 5PIN please use 1p...

Page 13: ...lease check if the switch and the transformer has power out u Check if the power input of the IC board is normal u Check if the cable connect to the display loose u Change the main board to see if it is normal u Chang the display LED not light u When connect to the electricity did the led flash one time If so the power source is normal If not please check if the switch and the transformer has powe...

Page 14: ...ion Input voltage AC 100V 264V 47 63HZ Consume 120W Lamp Type High Power LED 3W SMD3535 Lamp Spec R 6PCS G 8PCS B 8PCS W 8PCS A 6PCS LED Lifespan 50000 100000 hours LED Drive PWM 400HZ 16666 grades Drive Current 700mA Control Signal DMX512 auto run Control mode stand alone master slave Channel 5CH 7CH 9CH 11CH Color effect RGBAW mixing Beam Angle 10 40 degree zoom Effects Dimming Strobe Gradual di...

Reviews: