MULTIMATIC 2110 2309
                       3110 3309

EN

ALARMS 

A1: LACK OF WATER ALARM.

!

 Warning:

 

Failure verification: LED LIGHT FAILURE INTERMITTENT.
Final failure: LED LIGHT FAILURE ON.

!

 Description: 

If the system detects lack of water in the inlet during more than 10 seconds, it will stop the pumps and the ART will 

be activated. If there is installed an external device as a level sensor, when this one detects lack of water it will stop inmediately 
the pumps.The system will show the message of lack of water.

!

 System reaction: 

After 5 minutes ART system will start again the first pump during 30 seconds, trying to restore the system. In 

case of persisting the lack of water, it will try it again every 30 minutes for 24 hours. If after all these cycles , the system still 
detects lack of water, pumps will remain permanently off until the damage will be repaired.

!

 Solution: 

There is a lack of water in the inlet,   it has been activated the safety system: you should verify the feeding of the 

hydraulic network. The pumps can be primed using the push-button START/STOP ( the led light AUTOMATIC should be off, if it 
is not, press the push-button to disable

 it).

A2: OVER-INTENSITY ALARM.

A3: DISCONNECTED PUMP ALARM.

!

  Warning:

Final failure: LED LIGHT FAILURE ON.

!

 Description: 

The system has detected that the pump does not answer and has disconnected it to avoid worst damages. The 

MULTIMATIC has three 16 A delayed fuses. In case of pumps with another consumption, the suitable fuses should be chosen.

!

 System reaction: 

 The working mode EW (Emergency Working)  is activated allowing the system to continue working

!

 Solution when secondary pump is disconnected: 

The state of the fuses should be verified and they should be replaced if it is 

necessary (Fig 2). The wound of the motor and the pump consumption should be also verified. Once the problem have been 
solved the operation will be restored  going to the "INSTALLATION" menu (see the chapter configuration) and  introducing the  
adequate intensity values.  

!

 Warning: 

Failure verification: LED LIGHT FAILURE INTERMITTENT.
Final failure: LED LIGHT FAILURE ON.

                        number of attempts

!

  Description: 

The  system  pumps  are  protected  against  over  currents  by  mean  of  the  intensity  values  established  in  the 

installation menu. These over currents are produced generally by dysfunctions in the pump or in the electric supply.

!

 System reaction: 

When detecting the thermal failure, the system will test the pumps for the dection of the affected one. Once 

detected  it  will  be  automatically  excluded.  The    system  will  try  again  to  restart  the  excluded  pump  when  the  demand  of 
consumption require it. The control system will carry out 4 attempts in this circumstances. If the system remain locked after the 
4th attempt, the  pump will remain definitively out of order and system will continue working provisionally in EW  mode until the 
damage could be repaired.

!

 Solution: 

Verify the state of the pump, for example the impeller could be blocked. Verify intensity values introduced in the 

configuration menu ( it is always recommended to introduce intensity values 15% over the nominal pump intensity). Verify if 
there is any fuse damaged. Once the problem have been solved the operation will be restored  going to the "INSTALLATION" 
menu (see the chapter configuration) and  introducing the  adequate intensity values.  

A4: ACCUMULATION ALARM.

!

 Warning

Final failure: LED LIGHT FAILURE ON.

!

 Description: 

The system  analyzes periodically the state of the expansion tanks of the  hydraulic installation. 

!

 System reaction: 

If there is not enough accumulation, the system will continue working but is highly recommended to repair it 

immediatly .

!

 Solution:

The system has detected that the expansion tanks are damaged.  The load of air, the state of the membrane and the 

state of the sphere should be verified.  If it is necessary, you should replace them.  

A5: TRANSDUCER DAMAGED ALARM.

!

 Warning:

Final failure: LED LIGHT FAILURE ON.

!

 Description: 

The transducer damages are showed in the   SPEEDMATIC´s LCD screen. When this alarm is produced   we 

should contact with the technical service.

!

 System reaction: 

The device operation is interrupted.

!

 Solution:

 Contact with technical service.

BLANK SCREEN.

!

 Warning: 

Blank screen.

!

 Solution:

 Check the electric supply. In case of being in right conditions,  the general fuse, located in the main plate (fig 2) should 

be verified.  

In case of simultaneous alarms, they are showed in the LCD screen successively every 3 seconds.When we quit the automatic mode 
and go to manual mode, pressing  the pushbutton "AUTOMATIC" all the alarms are restored with the exception of alarms 2 and 3. We 
should verify the fuses and introduce again the intensity values in the installation MENU.

WARNING: 

MULTIMATIC has a volt-free contact with 1 A of maximum intensity for the transmission of diferent types of signal   

(optical, acoustics, etc). See connections diagram Fig. 5.

ALARM A1
LACK OF WATER

A2 ALARM
OVER-INTENSITY  P2 4

A3 ALARM
DISCONNECTED PUMP

___

A5 ALARM
TRANSDUCER DAMAGED

A4 ALARM
ACCUMULATION

8

Summary of Contents for MULTIMATIC 2110

Page 1: ...Risk by electric shock Risque de choc lectrique Riesgo por energ a el ctrica Danger par choc lectrique Risk for people and or objects Rischio per le persone e o per gli oggetti Riesgo para personas y...

Page 2: ......

Page 3: ...ndica lavornado nella pompa 2 ON P3 giallo Aceesso indica lavorando nella pompa 3 solo nel modello 3110 3309 1 cran LCD multifonction les diff rents param tres y sont affich s au cours de la configura...

Page 4: ...MULTIMATIC 2110 2309 3110 3309 Fig 2a 2110 3110 BODY CONNECTIONS COLLEGAMENTO CORPO CONEXIONES CUERPO CONNEXIONS SUR L APPAREIL DE COMMANDE Pump 3 fuse Fusibili pompa 3 Fusible bomba 3 Fusible pompe 3...

Page 5: ...a un dispositivo di montaggio independente del tipo 1B con software di classe A 1B con software de clase A Seg n EN 60730 1 el equipo es un dispositivo de montaje indepediente del tipo 1B con software...

Page 6: ...o opcional excepto mod 2110 Niveau minimum Optionnel sauf mod 2110 Minimal level optional only for mod 2110 Livello minimo facoltativo soltanto mod 2110 Nivel m nimo opcional s lo mod 2110 Niveau mini...

Page 7: ...e programmed pressures Start and stop pressure values shall be programmed according with section CONFIGURATION items 7 9 following next criteria Hm Max water column height in m It depends on the numbe...

Page 8: ...cs MULTIMATIC control must be connected in vertical position Fig 7 the inlet port 1 male directly to the main pump discharge and the outlet port 1 male at the main network ELECTRIC CONNECTION Fig 2 5...

Page 9: ...alternated operation sequence it could be pump 1 or 2 for type 2110 2309 and 1 2 or 3 for type 3110 3309 By mean of keys p q choose the desired pressure values 0 1 2 6 3 4 4 bis 5 7 9 9 bis 8 10 11 1...

Page 10: ...est the pumps for the dection of the affected one Once detected it will be automatically excluded The system will try again to restart the excluded pump when the demand of consumption require it The c...

Page 11: ...te Per determinare le pressioni di avviamento e paro di ogni una delle pompe il MULTIMATIC dovr essere programato secondo specificato nei punti 7 9 del capitolo CONFIGURAZIONE e d accordo con i seguen...

Page 12: ...Per raggiungere un ottima installazione raccomandabile usare tutte le pompe con le stesse caratteristiche Lo MULTIMATIC dovr essere installato in posizione verticale fig 7 collegato alla bocca di entr...

Page 13: ...lo 3110 3309 3 pompe Procedere uguale come nel punto 3 MULTIMATIC 2110 2309 3110 3309 Correggere i valori mediante p q per memorizzare dati Dopo ogni ENTER si succedono automaticamente i diversi scher...

Page 14: ...l problema di detta pompa per restabilire il suo funzionamento agire sul menu INSTALLAZIONE vedere confugurazione e introdurre i valori di intensit adeguati A3 ALARMAPOR BOMBADESCONECTADA Segnalazione...

Page 15: ...erminar las presiones de arranque y paro de cada una de ellas el MULTIMATIC deber ser programado seg n se especifica en los puntos 7 9 del cap tulo CONFIGURACI N y de acuerdo con los siguientes criter...

Page 16: ...n utilizar los fusibles adecuados INSTALACI N HIDRAULICA Fig 7 Es indispensable instalar una v lvula de retenci n a la aspiraci n de cada bomba Para lograr una instalaci n ptima se recomienda usar tod...

Page 17: ...as p q establecer el valor de presi n deseado 0 1 2 6 3 4 4 bis 5 7 9 9 bis 8 10 11 12 13 10 bis S lo en modelo 3309 3 bombas Proceder igual al punto 1 MULTIMATIC 2110 2309 3110 3309 Corregir valores...

Page 18: ...lucionado el problema de dicha bomba para restablecer su funcionamiento se deber ir al menu INSTALACI N ver CONFIGURACI N y restablecer los valores de intensidad adecuados A3 ALARMAPOR BOMBADESCONECTA...

Page 19: ...pompes du groupe selon les pressions programm es Pour d terminer les pressions de d marrage et d arr t de chaque pompe le MULTIMATIC doit tre programm comme sp cifi aux points 7 9 du chapitre CONFIGU...

Page 20: ...vec consommations diff rentes on doit utiliser les fusibles appropri s INSTALLATION HYDRAULIQUE Fig 7 Avant l installation hydraulique il est indispensable installer un clapet anti retour l aspiration...

Page 21: ...3 en mod 3009 Avec les touches r gler la valeur de pression d sir e 0 1 2 6 3 4 4 bis 5 7 9 9 bis 8 10 11 12 13 10 bis Seulement sur le mod le 3309 3 pompes Proc der comme dans le point 1 MULTIMATIC...

Page 22: ...FIXE l Description El sistema ha detectado que la bomba no responde y la ha desconectado para evitar su deterioro El MULTIMATIC dispone de un grupo de tres fusibles de 16 A retardado para cada bomba p...

Page 23: ...2001 UNE EN 61000 3 3 1997 CORR 1999 A1 2002 DECLARACI N DE CONFORMIDAD CE COELBO CONTROL SYSTEM S L Declaramos bajo nuestra responsabilidad que los materiales designados en la presente est n conforme...

Page 24: ......

Reviews: