C005905_04_CR1000_User_Manual
6.0 - Reading Ranges
Note: working ranges are a combination of both the wide and high density fields. All samples were high quality codes
and were read along a physical center line at a 10° angle. Default AGC settings were used. Accuracy= +/- 10%.
3
7.0 - Reader Feedback
Scenario
Top LED Light
Sound
CR1000 Successfully
Powers Up
Green LED Flashes
1 Beep
CR1000 Successfully
Enumerates with Host
(via cable)
Once Enumerated,
the Green LED turns Off
1 Beep
Attempting to Decode
Green LED Light is Off
None
Successful Decode and
Data Transfer via Cable
Green LED Flashes
1 Beep
Configuration Code Successfully
Decoded and Processed
Green LED Flashes
2 Beep
Configuration Code successfully
decoded but wasn’t
successfully processed
Green LED Flashes
4 Beeps
CR1000 Performance
Test Code
Min Inches (mm)
Max Inches (mm)
3 mil Code 39
3.1” (80 mm)
4.0” (102 mm)
7.5 mil Code 39
1.3” (33 mm)
7.2” (182 mm)
10.5 mil GS1 DataBar
0.8” (20 mm)
8.7” (220 mm)
13 mil UPC
1.1”(28 mm)
11.0” (280 mm)
4.2 mil Data Matrix
1.9” (48 mm)
4.3” (110 mm)
5 mil Data Matrix
1.7” (43 mm)
4.5” (115 mm)
6.3 mil Data Matrix
1.3” (33 mm)
5.9” (150 mm)
10 mil Data Matrix
0.8” (20 mm)
7.1” (180 mm)
20.8 mil Data Matrix
1.1” (28 mm)
13.5” (343 mm)