EN
G
LI
S
H
9
Low
capacity,
low
pressure.
Max. suction head exceeded.
Check suction head (max. 8 m).
Max. pressure head exceeded. Check pressure head (max. 48 m).
The suction hose’s foot valve is
above water level.
Move it so that it is below
the water level.
Dirt in the pump.
Remove any dirt or deposits.
Pump does
not stop.
Loose tap or leaking pipe.
Check and tighten or seal.
Pump starts
and stops all
the time.
Loose tap or leaking pipe.
Check and tighten or seal.
Faulty diaphragm.
Replace diaphragm and fill with air.
Air pressure in the tank too low.
Check and increase (to 1.5 bar).
Responsible disposal
This symbol indicates that this product should not be disposed of with
general household waste. This applies throughout the entire EU. In order
to prevent any harm to the environment or health hazards caused by
incorrect waste disposal, the product must be handed in for recycling
so that the material can be disposed of in a responsible manner. When
recycling your product, take it to your local collection facility or contact
the place of purchase. They will ensure that the product is disposed of in
an environmentally sound manner.
Specifications
Rated power
1300 W
Rated voltage
220–240 V AC, 50 Hz
Tank volume
20 litres
Max. pump capacity
83 l/min
Max. pressure head
48 metres
Max. suction head
8 metres
Hose connections
R25 (1
″
) female
Power Lead
1.5 metres