On completion of the gas conversion, replace gas
type identification labels located at:-
- Rear of unit, above the gas connection.
- Beside the rating plate.
Before leaving the converted installation;
1. Check all gas connections, including the pilot
burner injector base connection, for leakage
using soapy water or other gas detecting
equipment.
2. Carry out a ‘Commissioning’ check of the
appliance as shown in Installation Section of this
manual.
3. Ensure any adjustments done to components
that have adjustments / settings paint sealed,
these are to be re-sealed.
NOTE: If it is not possible to get the appliance to
operate correctly, shut ‘
Off’
gas supply and
contact supplier of this appliance.
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
- All Markets
NOTE: (*) Measure burner operating pressure at the manifold pressure test point with the main burner
operating at 'High Flame' setting. Operating pressure is ex-factory set, through the appliance
regulator and is not to be adjusted, apart from when carrying out gas conversion, if required. Refer
to the details in this section for further details.
Main Burner Injectors
Ø 1.00mm
Ø 0.65mm
Main Burner Injectors (Qty)
18
18
Main Burner Primary Air
6.0mm
6.0mm
Pilot Burner Injector
0.35mm
Fully In (C.W.)
0.25mm
Fully In (C.W.)
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.00 kPa
2.65 kPa
Gas Regulator Cap Screw