NOTE:
Water connection shall be installed in accordance
with local water regulations in force and the
applicable standard / code, e.g. PCA in Australia.
A cold water supply must be connected to the
water inlet connection (R
1
/
2
" BSP), located as
shown in the drawings in the ‘Specifications
Section’.
Water connection should be plumbed, in
accordance with National / Local Codes covering
installation.
Water inlet pressure must be as follows:-
Minimum water supply pressure 150 kPa (22 psi).
Maximum water supply pressure 550 kPa (80 psi).
Waste water is drained from the appliance work
surface by means of a waste water collection
system at the rear of the work surface.
Each model is fitted with a drain / overflow outlet on
the left underside of the appliance.
The drain outlet can be extended in order to exit
above a tundish or can be plumbed to a drain
outlet.
Drain connection is 1
1
/
2
" BSP, drain / overflow.
The following commissioning checks must be carried
out before the Gas Stock Pot is handed over for use,
to ensure the unit operates correctly and the
operator(s) understand the correct operating
procedure.
1. Before leaving new installation;
a. Check the following functions in accordance
with operating instructions specified in
‘Operation’ section of this manual.
Light the Pilot Burner.
Light the Main Burner.
b. Ensure that each operator has been
instructed in areas of correct lighting,
operation and shutdown procedures for the
appliance.
2. This manual must be kept by the owner for future
reference and a record of
Date of Purchase
,
Date of Installation
and
Serial Number of Unit
recorded and kept with this manual.
(These
details can be found on Rating Plate attached to
lower R/H side of side panel.
NOTE:
If it is not possible to get the appliance to operate
correctly, shut ‘
Off’
the gas supply and contact the
supplier of this unit.