background image

1.  Cobra Gas Stock Pots have been designed to 

provide simplicity of operation and 100% safety 
protection. 

2.  Improper operation is almost impossible, 

however bad operation practices can produce 
a poor quality product.  To use this Gas Stock Pot 
correctly, please read the following sections 
carefully; 

 

 

A commercial heavy duty, gas fired, high 
performance Stock Pot designed for Asian style  
commercial cooking, using LPG (Propane) or  
Natural Gas. 

 

The Stock Pot is only available in single Duckbill 
style main burner option which is fitted 

with a 

pilot burner.  The main burner is controlled by a 
single main burner gas valve and the pilot burner 
has a separate pilot burner gas valve. 

 

The Stock Pot is fitted with flame failure 
protection to control both the main burner and 
pilot burner. 

The Telescopic Water Filling Arm can be used for 
filling the Stock Pot cooking pans with water for 
cooking purposes, or can be used for cleaning 
down the Stock Pot table at the end of the cooking 
process. 

1.  To operate the Water Valve facility on the Stock 

Pot, a Water Valve is provided on the control 
panel. 

2.  An adjustable Water Filling Arm is provided on 

the splashback which can be used to fill 
receptacles or for Stock Pot cleaning. 

3.  To operate the Water Filling Arm, swing the arm 

over the cooking pan or where required.  The 
length of the arm can be adjusted by 
slackening the knurled adjuster on the arm. 

G

REAT

 

CARE

 

MUST

 

BE

 

TAKEN

 

BY

 

OPERATOR

TO

 

USE

 

THE

 

GAS

 S

TOCK

 P

OT

 

SAFELY

TO

 

GUARD

 

AGAINST

 

RISK

 

OF

 

INJURY

 

AND

 

FIRE

 

U

SER

 C

ARE

 

IS

 

REQUIRED

 

WHEN

 

TURNING

 ‘O

N

’ 

THE

 

MAIN

 B

URNER

S

 O

PEN

 F

LAME

 

DO NOT 

LEAVE

 

THE

 

GAS

 S

TOCK

 P

OT

 

UNATTENDED

 

DURING

 

OPERATION

 

T

URN

 ‘O

FF

’ 

THE

 

MAIN

 B

URNER

 F

LAME

 

BEFORE

 

REMOVING

 

THE

 S

TOCK

 P

OT

 

POT

 

FROM

 

THE

 

BURNER

 

DO NOT 

USE

 

FLAMMIBLE

 

SOLVENTS

 

AND

 

CLEANING

 

AIDS

 

ON

 

OR

 

IN

 

CLOSE

 

PROXIMITY

 

TO

 

THE

 

GAS

 S

TOCK

 P

OT

 

WHILST

 

THE

 S

TOCK

 P

OT

 

IS

 

STILL

 HOT. 

Water Filling Arm 

Knurled  

Adjuster 

Gas Safety 

Valve 

Pilot Burner 

Gas Valve 

Main Burner 

Gas Valve 

Water Valve 

Summary of Contents for CSP6

Page 1: ...242360 1 Gas Stock Pot Model CSP 6 I N S T A L LA T I ON A N D OP E R A T I ON M A N U A L ...

Page 2: ...rvice tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 327 5575 fax 44 121 327...

Page 3: ...ts Unpacking Location Clearances Gas Connection Water Connection Drainage Connection Commissioning Operation Guide Description of Controls Using the Telescopic Water Filling Arm Lighting the Pilot Burner Lighting the Main Burner Turning OFF the Main Burner Turning OFF the Pilot Burner General Daily Cleaning Weekly Cleaning Periodic Maintenance Gas Conversion Procedure Gas Specifications ...

Page 4: ...TY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT A...

Page 5: ...Pot is only available as a single burner model The module is fitted with a Duckbill type burner A commercial heavy duty gas fired high performance Stock Pot designed for commercial cooking using LPG Propane or Natural Gas This model is delivered completely assembled Ensure that the adjustable feet are securely attached NOTE This appliance is fitted with adjustable feet to enable the appliance to b...

Page 6: ...ications section in this manual for further details Input Rating N H G C 70 MJ hr 70 MJ hr Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 1 0 kPa 2 65 kPa Gas Connection BSP Male 70 MJ hr 70 MJ hr Input Rating N H G C Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 1 0 kPa 2 65 kPa Gas Connection BSP Male Input Rating N H G C 70 MJ hr 70 MJ hr 80 MJ hr ...

Page 7: ...5 Overall Dimensions 1230mm depending on Leg Adjustment 600mm 800mm 600mm 180mm Adjustable Suits up to 150ltrs ...

Page 8: ...e equipment and parts for damage Report any damage immediately to the carrier and distributor Report any deficiencies to the distributor who supplied the appliance Check that the available gas supply is correct to that shown on the rating plate located on the lower RH Side of the appliance 1 This appliance must be installed in a suitably ventilated room to prevent dangerous build up of combustion ...

Page 9: ...r into the gas supply line as close to the appliance as possible NOTE The gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per Gas Conversion Section in this manual Ensure regulator is converted to the correct gas type that the appliance will operate on Regulator outlet pressure is fixed ex factory for gas type that regulator is converted to and it ...

Page 10: ...h or can be plumbed to a drain outlet Drain connection is 11 2 BSP drain overflow The following commissioning checks must be carried out before the Gas Stock Pot is handed over for use to ensure the unit operates correctly and the operator s understand the correct operating procedure 1 Before leaving new installation a Check the following functions in accordance with operating instructions specifi...

Page 11: ...r for cooking purposes or can be used for cleaning down the Stock Pot table at the end of the cooking process 1 To operate the Water Valve facility on the Stock Pot a Water Valve is provided on the control panel 2 An adjustable Water Filling Arm is provided on the splashback which can be used to fill receptacles or for Stock Pot cleaning 3 To operate the Water Filling Arm swing the arm over the co...

Page 12: ...and hold the Gas Safety Valve depressed and manually light the Pilot Burner 5 Keep holding the Gas Safety Valve depressed for 30 seconds after the pilot burner is lit to allow the thermocouple to warm up 6 Release the Gas Safety Valve the pilot burner should remain alight 7 If the pilot burner does not ignite repeat Items 3 to 6 above 1 Turn On the Main Burner Gas Valve anti clockwise to the setti...

Page 13: ...the detergent or cleaning material has been entirely removed after each cleaning process 1 Clean the interior and exterior surfaces of the Gas Stock Pot with a hot water and mild detergent solution and a soft scrubbing brush 2 Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cleaner when appliance is cold and rub in directi...

Page 14: ...ical parts should be checked and adjusted periodically by a qualified service person If any small faults occur have them attended to promptly Don t wait until they cause a complete breakdown It is recommended that the appliance is serviced every 12 months If appliance is not used for long periods close the gas shut off valve upstream of the appliance and clean the appliance thoroughly ...

Page 15: ...ersists Gas control valve is defective and needs replacement Call service provider Pilot Burner delay in ignition of main burners Check operating pressure as stated in Installation section Check gas supply Call service provider Check pilot flame size Pilot flame for main burner ignition should be approximately 1 inch long Check pilot burner injector size is correct See Specifications section Check...

Page 16: ...ove the blanking screw at the base of the pilot burner assembly 2 Remove the pilot injector and spring taking care not to lose the spring 3 Fit the spring to the replacement pilot injector and using a small flat bladed screwdriver screw the pilot injector fully home 4 Light the pilot burner and ensure the flame is the correct size NAT Gas LPG Butane Only NOTE Gas regulator supplied is convertible ...

Page 17: ... get the appliance to operate correctly shut Off gas supply and contact supplier of this appliance DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES All Markets NOTE Measure burner operating pressure at the manifold pressure test point with the main burner operating at High Flame setting Operating pressure is ex factory set through the appliance regulator and is not to be adjusted apart from when...

Page 18: ...manual Part No Description 242852 SPILL TRAY STOCK POT 243359 DRAIN CHANNEL COVER CSP6 242618 PILOT HOOD 242556 POT STAND STOCK POT 243185 BURNER TUBE 3 4 20mm x 12 CSP6 243097 BURNER DUCKBILL 18 JET 0 70mm LPG 242547 BURNER DUCKBILL 18 JET 1 25mm NAT 242552 INJECTOR DUCKBILL 0 70mm LPG 242555 INJECTOR DUCKBILL 1 25mm NAT 237077 PILOT SUPPLY FLEX TUBE STST 1 4 x 18 240877 GAS VALVE 3 4 BSP LEVER H...

Page 19: ......

Reviews: