background image

15

Nothing comes close to a Cobra

®

Turning Your Inverter On or Off

Be sure to have your power inverter properly installed before attempting to 
turn the unit On (see “Installation” page 6).

To Turn the Power Inverter On:

1. If a DC power supply is being used as the power source, switch it On. 

2. On the left side panel, switch the On/Off Switch to On.

The inverter is now ready to deliver AC power to your loads. If several loads 
are to be operated by the inverter, turn them On separately, after the inverter 
has been turned On. This will ensure that the inverter does not have to deliver 
the starting currents required for all the loads at once.

To Turn the Power Inverter Off:

1. On the left side panel, switch the On/Off Switch to Off.

14 English

Remote On/Off Switch

The Remote On/Off Switch allows you to turn On or Off the CobraMarine

Power

Inverters from a convenient location — up to 20 feet (6 meters) away — while the
inverter is mounted out of reach and sight.

To Install Remote On/Off Switch:

1. Select a location that is convenient for operation (and 

where the Remote On/Off Switch assembly and cable 
does not interfere with the driver or a passenger). 
Be sure there is adequate clearance behind the panel 
before drilling or cutting.

2. Cut out the mounting template included with this manual 

on a separate card.

3. Position the template on the wall/surface where you want 

to install the Remote On/Off Switch.

4. Mark the location of the two screw holes and the square 

to be cut out for the switch board.

5. Create two pilot holes for the screws.

6. Cut out the square from the template to accommodate 

the switch board. 

If cutting a square on the wall is not desirable, use bushings
(not included) to raise the switch assembly so that switch 
board clears the wall.

7. Fasten the switch plate using the two screws (included).

8. Connect the cable (RJ-11 connector) to the inverter’s 

remote jack.

If more than 20 feet of cable is required, use a 1-to-1 female
connector and a 4-wire conductor, phone extension cord with 
RJ-11 male connectors on each end to extend the cable. 
50 feet of cable is maximum recommended.

Remote On/Off Switch

Installation

Cut Out Template

Mark Location

Drill Pilot Holes

Cut Out Square

Fasten Switch Plate

Connect Cable

Power On or Off

Operation

On/Off Switch to On

On/Off Switch to Off

Continued...

Summary of Contents for CPI M 2200

Page 1: ...duct or not understand its many features please refer to this owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance serv...

Page 2: ...22 Warranty Warranty 23 Customer Assistance Maintenance 24 Product Service 24 Accessories and Order Form 26 Controls Indicators and Product Features Introduction Table of Contents Introduction Featur...

Page 3: ...atements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery fumes are presen...

Page 4: ...rous voltages are present at the battery terminals This problem does not occur with the vast majority of battery operated equipment Most use a separate charger or transformer that is plugged into the...

Page 5: ...be terminated with a lug or other connector that provides a secure low resistance connection For example if the power source is a battery the cable must be terminated with a battery terminal that cla...

Page 6: ...han longer DC wires cables CAUTION To avoid fire do not cover or obstruct ventilation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter must...

Page 7: ...ssential between the battery and inverter This is so it can deliver the maximum amount of energy to the load Use only copper wire Aluminum wire has about 1 3 more resistance than copper wire of the sa...

Page 8: ...es and should be performed by a qualified electrician CAUTION Do not connect the inverter and another AC source such as a generator or utility power to the AC wiring at the same time The inverter will...

Page 9: ...r for a specified length of time Example Reserve capacity a battery with a reserve capacity of 180 minutes can deliver 25 amperes for 180 minutes before it is completely discharged Example Ampere hour...

Page 10: ...the Remote On Off Switch assembly and cable does not interfere with the driver or a passenger Be sure there is adequate clearance behind the panel before drilling or cutting 2 Cut out the mounting te...

Page 11: ...o turn the inverter On or Off from a convenient location when the inverter is installed in an out of reach location Be sure to have your power inverter and Remote On Off Switch properly installed befo...

Page 12: ...r and Protection Indicators The Power and Protection Indicators include along with an audible alarm an over temperature indicator an amps meter a volts meter and an overload indicator Over Temperature...

Page 13: ...ut voltage exceeds 12V 0 3V The inverter will also shut down if the input voltage exceeds 15 75V 0 75V This protects the inverter against excessive input voltage Although the inverter has protection a...

Page 14: ...rranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty Cobra shall not be liable for any incidental consequential or other damages incl...

Page 15: ...to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals Be sure vents and fans are free of dust or debris Product Service If you have any questions about...

Page 16: ...y products includes CB Radios microTALK Radios Radar Laser Detectors Safety Alert Traffic Warning Systems Accessories GPS Global Positioning System HighGear Accessories Name Address No P O Boxes City...

Reviews: