3. Connect cables to the Power Input Terminals on right side panel of the inverter. The

red terminal is positive (+) and the black terminal is negative (-). Insert the bare ends
of the cables into the terminals and tighten the screws to clamp the wires safely.

4. Connect cables to the power source:

a. Connect each cable from the Negative (Black) Terminal of inverter to the 

Negative Terminal of the power source. Make a secure connection. 

b. Connect each cable from the Positive (Red) Terminal of the inverter to the 

Positive Terminal of the power source (the battery’s main fuse or the battery 
selector switch, if you are using one). Make a secure connection.

You might observe a spark when you make this connection, 
since current can flow to charge capacitors in the inverter. 

8

English

Connecting Cables (not included)

Power wire and wiring are very important to the performance of the inverter. 
Because the inverter has a low voltage, high current input, low resistance wiring 
is essential between the battery and inverter. This is so it can deliver the maximum
amount of energy to the load. 

Use only copper wire. Aluminum wire has about 

1

3

more resistance than copper 

wire of the same size, plus it is difficult to make good, low-resistance connections 
to aluminum wire.

We recommend #4 AWG copper cable (90°C insulation rating) as the minimum 
size for connections between the battery and inverter.

Keep the cable length as short as possible, no more than 4 feet (1.5 meters). 
This will keep the voltage drop to a minimum.

If the cable has too much voltage drop, the inverter may shut down when drawing
higher currents because voltage at the inverter may drop below 10 volts. If you
must use longer cables, choose thicker cables, such as #2 AWG, and trim the 
ends of the cable to fit the terminals.

To Connect the Cables Between the Inverter and the Battery:

1. Turn the On/Off Switch on the inverter to the Off position. If the power 

source is a DC power supply, switch it Off as well.

2. On the end of the cable that connects to the inverter, strip back the 

insulation about 

1

2

inch (1.25 cm), exposing the bare copper conductor.

Connecting Cables

Turn On/Off Switch to Off

Strip the Insulation

Insert Bare Cables

Continued...

Connect Cables

Summary of Contents for CPI M 2200

Page 1: ...duct or not understand its many features please refer to this owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance serv...

Page 2: ...22 Warranty Warranty 23 Customer Assistance Maintenance 24 Product Service 24 Accessories and Order Form 26 Controls Indicators and Product Features Introduction Table of Contents Introduction Featur...

Page 3: ...atements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery fumes are presen...

Page 4: ...rous voltages are present at the battery terminals This problem does not occur with the vast majority of battery operated equipment Most use a separate charger or transformer that is plugged into the...

Page 5: ...be terminated with a lug or other connector that provides a secure low resistance connection For example if the power source is a battery the cable must be terminated with a battery terminal that cla...

Page 6: ...han longer DC wires cables CAUTION To avoid fire do not cover or obstruct ventilation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter must...

Page 7: ...ssential between the battery and inverter This is so it can deliver the maximum amount of energy to the load Use only copper wire Aluminum wire has about 1 3 more resistance than copper wire of the sa...

Page 8: ...es and should be performed by a qualified electrician CAUTION Do not connect the inverter and another AC source such as a generator or utility power to the AC wiring at the same time The inverter will...

Page 9: ...r for a specified length of time Example Reserve capacity a battery with a reserve capacity of 180 minutes can deliver 25 amperes for 180 minutes before it is completely discharged Example Ampere hour...

Page 10: ...the Remote On Off Switch assembly and cable does not interfere with the driver or a passenger Be sure there is adequate clearance behind the panel before drilling or cutting 2 Cut out the mounting te...

Page 11: ...o turn the inverter On or Off from a convenient location when the inverter is installed in an out of reach location Be sure to have your power inverter and Remote On Off Switch properly installed befo...

Page 12: ...r and Protection Indicators The Power and Protection Indicators include along with an audible alarm an over temperature indicator an amps meter a volts meter and an overload indicator Over Temperature...

Page 13: ...ut voltage exceeds 12V 0 3V The inverter will also shut down if the input voltage exceeds 15 75V 0 75V This protects the inverter against excessive input voltage Although the inverter has protection a...

Page 14: ...rranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty Cobra shall not be liable for any incidental consequential or other damages incl...

Page 15: ...to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals Be sure vents and fans are free of dust or debris Product Service If you have any questions about...

Page 16: ...y products includes CB Radios microTALK Radios Radar Laser Detectors Safety Alert Traffic Warning Systems Accessories GPS Global Positioning System HighGear Accessories Name Address No P O Boxes City...

Reviews: