To Test the GFCI Outlet:

1. Turn the inverter On (see page 15 for details).

2. Plug a test lamp into the outlet.

3. On the GFCI Outlet, press the Test Button.

The Reset Button should pop out and power to the lamp should turn Off. 

If the lamp remains On, or if the Reset Button does not pop out, the unit is 
defective. Return the inverter to the place of purchase for replacement or service.

4. On the GFCI Outlet, push the Reset Button to return to regular operation.

16 English

NOTE The On/Off Switch turns the control circuit in the inverter On and Off. 
It does not disconnect power from the inverter.

When the switch is in the Off position, the inverter draws no current 
from battery. When it’s in the On position, but no power is being supplied 
to the load, the inverter draws less than 500 milliamperes from the battery. 
This is low current draw. It would take more than a week to discharge a 
100 ampere-hour battery at this rate depending on the age of the battery. 

Remote On/Off Switch

Remote On/Off Switch can be connected to the Remote Jack allowing you to turn
the inverter On or Off from a convenient location when the inverter is installed in an
out-of-reach location. Be sure to have your power inverter and Remote On/Off Switch
properly installed before attempting to turn the unit On (see “Installation” page 6). 

To Turn the Power Inverter On or Off:

1. On the left side panel of the inverter, switch the 

On/Off Switch to On.

2. Press the Remote On/Off Switch button to toggle 

On or Off. The remote On/Off Switch power indication 
light will remain lit when power is On. 

The inverter is now ready to deliver AC power to your loads. 
If several loads are to be operated by the inverter, turn them 
On separately, after the inverter has been turned On. This will
ensure that the inverter does not have to deliver the starting
currents required for all the loads at once.

Ground Fault Circuit Interrupter (GFCI) Outlet

The AC outlet on your CobraMarine

Power Inverter is a Ground Fault Circuit Interrupter

(GFCI). This protects you against hazardous electrical shock that could be caused by
dampness, faulty mechanism, worn cables, water spray, etc. 

Test the GFCI periodically to make sure it is operating properly.

Remote On/Off Switch

GFCI Test

Test Button

Test Load

On/Off Switch to On

On/Off Switch to On

Indicator Light

Reset Button

Operation

Operation

Summary of Contents for CPI M 2200

Page 1: ...duct or not understand its many features please refer to this owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance serv...

Page 2: ...22 Warranty Warranty 23 Customer Assistance Maintenance 24 Product Service 24 Accessories and Order Form 26 Controls Indicators and Product Features Introduction Table of Contents Introduction Featur...

Page 3: ...atements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery fumes are presen...

Page 4: ...rous voltages are present at the battery terminals This problem does not occur with the vast majority of battery operated equipment Most use a separate charger or transformer that is plugged into the...

Page 5: ...be terminated with a lug or other connector that provides a secure low resistance connection For example if the power source is a battery the cable must be terminated with a battery terminal that cla...

Page 6: ...han longer DC wires cables CAUTION To avoid fire do not cover or obstruct ventilation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter must...

Page 7: ...ssential between the battery and inverter This is so it can deliver the maximum amount of energy to the load Use only copper wire Aluminum wire has about 1 3 more resistance than copper wire of the sa...

Page 8: ...es and should be performed by a qualified electrician CAUTION Do not connect the inverter and another AC source such as a generator or utility power to the AC wiring at the same time The inverter will...

Page 9: ...r for a specified length of time Example Reserve capacity a battery with a reserve capacity of 180 minutes can deliver 25 amperes for 180 minutes before it is completely discharged Example Ampere hour...

Page 10: ...the Remote On Off Switch assembly and cable does not interfere with the driver or a passenger Be sure there is adequate clearance behind the panel before drilling or cutting 2 Cut out the mounting te...

Page 11: ...o turn the inverter On or Off from a convenient location when the inverter is installed in an out of reach location Be sure to have your power inverter and Remote On Off Switch properly installed befo...

Page 12: ...r and Protection Indicators The Power and Protection Indicators include along with an audible alarm an over temperature indicator an amps meter a volts meter and an overload indicator Over Temperature...

Page 13: ...ut voltage exceeds 12V 0 3V The inverter will also shut down if the input voltage exceeds 15 75V 0 75V This protects the inverter against excessive input voltage Although the inverter has protection a...