Chapter 3: Installation
64
System setup
System setup
To change a setting in the
SYSTEM SETUP
, do as follows:
1. Press the soft key
SETUP
. If it is not in the display, press the soft key
MORE
until
SETUP
appears.
2. Press the arrow soft key
or
to advance to
SYSTEM SETUP
.
3. Turn the selector wheel knob to go to a setting, then press
the selector wheel knob to change the setting.
4. Press
EXIT
to return to normal radio operation
.
SYSTEM SETUP
Description
System time & Date
View and set system time and date
Inactivity timeout
Inactivity time-out to exit functions (e.g. in
setup) and return to the application.
Range: 1 to 30 minutes, in 1 minute steps
Default: 10 min.
NMEA input (baud rate)
4800
Factory Defaults
Resets the radio to factory defaults.
SW version
Software version of the radio
S/N
Serial number of the radio
Password
If you need to change the identity of the
radio (MMSI number or ATIS code), contact
your local dealer.