28
2.3.8 Optional - External Alarm and Relay Connections
The connector plinth for the external alarms is located inside the repeater.
To connect external alarms or relay
1. Refer to section
2.2.6 for the external alarms and relay considerations.
2. Locate the alarms plinth inside the repeater.
Figure 2-29. Example of Repeater Showing the Location of the Alarms Plinth
3. Connect the alarm cords to the plinth according to the pin layout below (in the standard version Pins 14–
18 are not used).
Figure 2-30. External Alarm and Relay Pinout
Note the following
•
Four external alarm sources can be connected to the repeater:
•
It is required to configure the external alarm polarity (part of the setup procedure — Section
4.3.3).
1
External alarm 1A
2
External alarm 1B
3
External alarm 2A
4
External alarm 2B
5
External alarm 3A
6
External alarm 3B
7
External alarm 4A
8
External alarm 4B
9
Alarm +15V
10
Alarm 0V
11
Relay Output 1A
12
Relay Output 1B
13
GND
14
NC
15
NC
16
NC
17
NC
18
NC
Pin # Signal
Pin 1
Alarms Plinth
Route Alarms
Cable