background image

9

CONTENTS

Error (and Stop) 

See Chapter 4.2 for features and function of the Error line. 

 

See Chapter 5.4 for Error line connection options.

Note:

 A 

Stop

 signal can be sent on the 

Reset

 line or on the 

Error

 line. Ground-

ing either of these pins will stop the drive, but in different ways. See Chapter 4.2 for 
Error line function.

3.3  Using external braking circuit

The background: When a DC motor is rapidly deccelerating it acts as a generator. The 
generated energy pumps back into the drive, possibly higher the voltage in the motor 
power supply. Therefore if the used power supply rated voltage is greater than 80VDC, it 
is strongly recommended to use an external braking circuit which dumps and dissipates 
the generated extra Voltage and energy.

 

Working of braking circuits: A braking circuit monitors the motor power supply voltage. If 
the voltage level rises above a set level the braking circuit activates and powers a braking 
resistor. The braking resistor is used to dissipate the generated extra energy.

We supply braking circuit products which fits our drives and can be used to protect the 
drives and the system from regenerative overvoltage events. For more information please 
check our BRKC-xxx braking circuit devices datasheet.

!

Summary of Contents for DG4S Series

Page 1: ...DG4S series DC Servo drive...

Page 2: ...ectors 3 2 USB Main and Encoder connectors 3 3 Using external braking circuit 4 Indicators and faults 10 4 1 LED indicators 10 4 2 Fault conditions and Error handling 10 5 Installation of drive and ph...

Page 3: ...er supply s correct polarity connection wrong polarity connection of the Motor Power supply will cause permanent damage to the device Never disconnect the motor from the drive when power supply is con...

Page 4: ...C input Votlage may cause permanent dam age to the device Motor current model 08020 0 20 A Limited by drive at software set threshold maximum at 20A Motor current model 16035 0 35 A Limited by drive a...

Page 5: ...ency 1 1 1 MHz With 4x decoding Error line output current 0 50 100 mA 100mA continiously output current is destructive Switching frequency 20 20 20 kHz PID loop sampling time 1 65535 60usec User setab...

Page 6: ...s a positive and a negative connector section Each connection polarity has 2 pins for a 4 pins plug type scew terminal attachment For low power motors where the peak current rating of the motor is low...

Page 7: ...s other parts and from the PC Note The PRG01 USB programming stick is not the part of the DG4S drive package This product must ordered separately One programming stick can be used to configure any nu...

Page 8: ...both of them should not be con nected because connecting both could damage the device It also must be noted that the 5Volts connection does not have an overVoltage nor reverse polarity protection mak...

Page 9: ...the motor power supply Therefore if the used power supply rated voltage is greater than 80VDC it is strongly recommended to use an external braking circuit which dumps and dissipates the generated ex...

Page 10: ...e line can be pulled low by an external source CNC software E stop etc In this case the drive will stop and remain stopped When the pin is released the drive will remain stopped but can then be reset...

Page 11: ...nking Description This is a fault condition and indicates an overtemperature of the drive s metal case When this fault happens the drive cannot be reset until it cools down to under 65 C 5 Overcurrent...

Page 12: ...ackplate is bent to 90 and is mountable in the vertical and also in the horizontal orientation The drive s metal base plate acts as a heat sink for the drive and can become hot under heavy current ope...

Page 13: ...ncoder vendor supplied pre made cable of sufficient length then simply con nect those wires to an RJ45 plug These plugs are readily available at electronics supply stores in both crimp and IDS types I...

Page 14: ...in normal operation the error line is released by the drive and only the internal 100kOhm pullup resistors pulling the line to the internal 5 Volts potential The error line acts as an open collector...

Page 15: ...line low Releasing the line returns the line to a high 5V state It is only allowed to pull the error line low GND poten tial externally Pulling the line high with any external logic may cause the outp...

Page 16: ...ly resets and starts operation again If an internal fault occurs in any of the drives in this chain the commoned error reset line is pulled to GND potential by the drive which got the fault but becaus...

Page 17: ...ng The DC output should be smoothed with capacitors downstream of the rectifier using the following sizing rules 1000uF per amp up to 80V 2000uF per amp over 80V Connect each drive with separate feed...

Page 18: ...igned to power highly inductive loads like motors The problem is that the power supplies having too low capacitance on the outputs and the inductive kickback from the motors may rise the power supply...

Page 19: ...n incremental and TTL level type with square waves Absolute encoders are not supported An encoder with differential A A_ and B B_ channels must be used for position feed back from the motor to the dri...

Page 20: ...nder 10mA Q I like to control an AC servomotor with the drive is it possible A No The drive can only control brush type DC servomotors Q I have a disk type servomotor with coil resistance of lower tha...

Page 21: ...21 CONTENTS...

Page 22: ...22 CONTENTS For more information visit Please consider the enviroment before printing this document www cncdrive com...

Reviews: