![CNB SxB2xZ12F N User Manual Download Page 7](http://html1.mh-extra.com/html/cnb/sxb2xz12f-n/sxb2xz12f-n_user-manual_2627749007.webp)
◎ The forth DIP switch position sets the termination Impedance on the camera.
◎ When the controller is far away from the camera
(1:1 connection)
- An impedance mismatch can happen when the controller is far from the camera.
Set the termination impedance on the camera as well as the controller to match
the impedance.
◎ When connecting many cameras in the same network.
◎ The three DIP switch positions shown below sets the communication protocol.
Communication Protocol
Termination Impedance
Use the termination Impedance in the following cases:
ON
1
2
3
4
ON
1
2
3
4
NO
PROTOCOL
BAUDRATE
#1
#2
#3
0
PELCO-D
2400bps
OFF
OFF
OFF
1
PELCO-D
9600bps
ON
OFF
OFF
2
PELCO-P
4800bps
OFF
ON
OFF
3
11
10
◎ When connecting many cameras in the same network.
- The signal loss can happen when too many cameras are connected to the same
network. Set the termination impedance on the furthest camera only as well as
the controller. Do not turn on the termination impedance on other cameras.
◎ On the controller (Keyboard-type or DVR), make sure the same protocol and
baud rate are selected before controlling.
◎ Turn the camera’s power off before changing the protocol setting.
3
PELCO-P
9600bps
ON
ON
OFF
4
BOSCH
9600bps
OFF
OFF
ON
Others
Reserved
# 2
# 1
# n
Keyboard Controller/DVR
RS-485
Summary of Contents for SxB2xZ12F N
Page 1: ...Compact PTZ Dome Camera SxB2xZ12F N P User s Manual Ver 1 2 3810 0287A2 www cnbtec com...
Page 2: ...Compact PTZ Dome Camera SxB2xZ12F N P User s Manual Ver 1 2 www cnbtec com...
Page 24: ...45 44 Unit mm...
Page 25: ...www cnbtec com Compact PTZ Dome Camera SxB2xZ12F N P Ver 1 2...
Page 26: ......
Page 31: ...4 PTZ 59 58...
Page 32: ...61 60...
Page 47: ...91 90 mm...