D. SYSTEM OPERATION
3. CONTROL CENTER OPERATION
CONTROL CENTER GUIDE
a. Chlorine Output Lights (A) show level of chlorine output as a percentage of system capacity
b. Solid Power light (B) indicates the system is operating correctly
c. Service Light (C) indicates a system warning. See Troubleshooting section page
16
d. Polarity (D) indicates direction of current; reverses every 6 hours of operation automatically
e. Press Output Controls Up or Down (E) to increase or decrease system output
f. On / Off Switch (below operation panel) controls main power to system
IMAGE 5 - OPERATION PANEL
SYSTEM POWER UP
g. Engage Power switch by pressing to “On” position. As the system boots up, the lights will flash for about ten seconds. The
Power light will then remain solid; the Chlorine Output lights will display the selected chlorine output level. One of the
Polarity lights will also illuminate, indicating the direction of current.
h. Every six hours of system operation the polarity will change automatically, which prolongs the life of the cell and
minimizes build up between the cell blades.
i. If the power is interrupted (either by the pump turning off or by putting the Power switch into the off position), the system
will automatically reset to the setting when last powered on.
A
D
E
B
C