9
SURFACE MOUNT ROCKER CONTROL SWITCH
1. Route toggle control switch harness through surface mounting adapter.
2. Mark and drill pilot holes in the mounting surface using 3/31” (2.4mm) drill bit. Route wiring
harness though notch in mounting adapter. Secure switch assembly to mounting surface with self
tapping screws as shown. Tighten securely.
CONNECT RELAY HARNESS POWER CABLES TO CRANK BATTERY
A
Attach large red and black leads from relay harness to crank battery.
Red to positive (+) ------Black to negative (-)
HYDRAULIC MOTOR LIFT LUBRICATION
CAUTION!
The oil in the motor lift hydraulic system is under pressure when the jack plate is in
any position other than fully elevated (“UP”), or the h
ydraulic ram fully extended. Open the yellow
fill cap only when hydraulic ram has been fully extended.
1.
Cycle the Motor Lift several times from the full down to full up position.
2.
With Motor Lift
in the “Full
-
up” (hydraulic, ram fully extended) position,
slowly remove
yellow fill cap and check hydraulic fluid level. If needed, fill to the bottom of threads in oil
reservoir. (Use Power Trim and Steering Fluid or Dextron III ATF Fluid.)