8
FLUSH MOUNTING ROCKER CONTROL SWITCH
NOTE
: Mounting surface must be a minimum of 1/16
th
inches (1.6 mm) or a maximum of ½”.
(12.7 mm) thick for toggle control switch assembly to tighten securely.
1.
Using a 2-1/8
th
inch (54 mm) hole saw, drill out marked area of mounting surface.
2.
Route toggle control switch harness through bezel retainer.
NOTE
: The bezel retainer is mounted onto the switch bezel before placement into opening. A gap
between the bezel and the bezel retainer must be 1/8” (3.2 mm) greater than the thickness of the
mounting surface.
3.
Attach the bezel retainer to bezel using (2) screws.
4.
Install switch harness through mounting surface.
NOTE
: Install into position by placing
pressure on screw heads to maintain a gap between bezel retainer and bezel. Push the
assembly into the opening and then tighten screws securely.