![CMOSTEK CMT2310A Operation Manual Download Page 29](http://html1.mh-extra.com/html/cmostek/cmt2310a/cmt2310a_operation-manual_2627475029.webp)
AN241
www.hoperf.com
Copyright © By HOPERF
V0.4 | Page 29/41
Figure 3-8. Only Tx Mode interface
(
in processing
)
No.
Function
Description
1
Packet information
Display the current packets numbers. For each packet sent, the number is increased by 1.
The test stops automatically after it ends in sending the packet. The maximum number of
packets is 1000.
2
Operation guide
The corresponding K1~K5 operation guide is shown in the figure above
:
Short press K1
(
Tx /
)
and enter into / suspend the packet sending process.
Suspending doesn’t reset the packet counter
;
Short press K2
(
)
and return to the upper menu, reset the packet counter
(
that
is, clearing
)
Note
:
1. Since the CMT2310A-EM board is equipped with reserved Current Detect jumper terminals, the current
consumption under sending packet mode of CMT2310A can be tested by combining this mode.
However,
in this sending mode, the current will be fluctuated and not stable for the reason that there will be a brief
intermittent between sending packets arising from standby mode.
2. In the process of sending a packet, LED1 flickers, and its flickering rhythm is related to the packet
consumption time. When it pauses or exits from Tx, LED1 will be extinguished accordingly.
3.5 Only Rx Mode
After selecting the "Only Rx Mode", press K1 " " in the main interface to enter the only Rx Mode, as shown in
Figure 3-9 below.
CM T2 31 0A EB GU I
86 5M Hz 2F SK R x 0 00
20 kbp s 10 kHz
4. Chanel signal
Rx
1. Frequency
band
2.Modulation/demodu-
lation mode
5. Data rate/
frequency offset
parameter
6. Operation
guide
3. Rx mode
Figure 3-9. Only Rx Mode interface
No.
Function
Description
1
Frequency band
Display the selected frequency band as shown in the figure above. It indicates that the
start frequency of the selected frequency band is 865000kHz.