AN241
www.hoperf.com
Copyright © By HOPERF
V0.4 | Page 16/41
No.
Function
Description
1
Rolling option area
In this area, different coding format can be selected by pressing K3 or
K4
:
NRZ
(
Non-Return-Zero encoding
)
Whitening
(
Whitening encoding
)
Manchester
(
Manchester encoding
)
FEC RSC
FEC NRNSC
After selecting the corresponding modulation mode, press K2 or K5 to
confirm the selection and return to the upper menu (i.e. the main menu).
Note
:
1. The Whitening code is in the PN9-CCITT mode (according to the default option of RFPDK), and the
Whitening Seed value is set to 0x01FF
;
2. The Manchester encoding uses
logic_1=2
’
b01
,
logic_0=2
’
b10, and SyncWord enables the
Manchester code
;
3. The FEC RSC and FECNRNSC are compatible with the specifications defined by IEEE 802.15.4g
2.11 CRC Select Submenu
Select the
9 CRC Select
and press K5 to enter the submenu, as shown in Figure 2-12.
CM T2 31 0A EB GU I
9 CR C S el e ct
CR C1 6 C CI TT
1. Rolling option area
Figure 2-12. CRC Select submenu interface
No.
Function
Description
1
Rolling option area
In this area, different CRC verification format can be selected by pressing
K3 or K4
:
CRC16-CCITT
CRC16-IBM
CRC32 0x04C11DB7
After selecting the corresponding modulation mode, press K2 or K5 to
confirm the selection and return to the upper menu (i.e. the main menu).