background image

www.cls-led.com

www.cls-led.com

7

8

PROGRAMMING TABLE

 

PROGRAMMING TABLE

 

DMX  Function 

Data 

Parameters 

Description 

CH1  Set address  

001 to 255 

0 = no change 

Use this DMX channel to set address from 001 to 

255. The configured DMX address is called “n” 

1…255  DMX address = 1…255 

CH2  Set address 

256 to 508 

no change 

Use this DMX channel to set address from 256 to 

508. The configured DMX address is called “n” 

1…255  DMX address =  256…508 

CH3  Static 

behavior 

no change  

If no DMX is present the fixture will respond like 

set in this function.  

last DMX value 

output off 

load static values 

CH4  Soft dim 

no change   

Soft dim will interpolate between the DMX 

values. This function makes the dim curve 

smoother 

off 

on 

CH5  Master 

control 

no change  

If master is first channel is selected the channel 

will be DMX channel “n”. If master is last channel 

is selected the channel will be “n+x” 

(“x” is calculated in the output patch). 

no master used 

master is first channel 

master is last channel 

CH6  Output 1 

patch 

no change 

Each output channel can be patched to respond 

to the desired DMX channel. This enables the 

user to mix up the colours according to the 

controller that is used. 

 

Example: all outputs are patched as 1 

All outputs will be controlled by DMX channel 

“n”. If master is used total DMX channels will be 2 

otherwise it uses 1 channel (“x” = 1). 

 

Example: output 1&2 are patched as 1 and 3&4 

are patched as 2 

Output 1&2 will be controlled by DMX channel 

“n”.  

Output 3&4 will be controlled by DMX channel 

“n+1”.  

If master is used total DMX channels will be 3 

otherwise it uses 2 channels (“x” = 2). 

 

 

DMX channel n 

DMX channel n+1 

DMX channel n+2 

DMX channel n+3 

CH7  Output 2 

patch 

no change 

DMX channel n 

DMX channel n+1 

DMX channel n+2 

DMX channel n+3 

CH8  Output 3 

patch 

no change 

DMX channel n 

DMX channel n+1 

DMX channel n+2 

DMX channel n+3 

CH9  Output 4 

patch 

no change 

DMX channel n 

DMX channel n+1 

DMX channel n+2 

DMX channel n+3 

CH10  Static output 

no change 

Each output channel can be set to an static 

intensity.  

 

If no DMX is present and Static behavior is set to 

“load static values”. The outputs will be set to the 

configured intensity values. 

 

 

 

 

 

 

output off 

2…255  intensity 2…255 

CH11  Static output 

no change 

output off 

2…255  intensity 2…255 

CH12  Static output 

no change 

output off 

2…255  intensity 2…255 

CH13  Static output 

no change 

output off 

2…255  intensity 2…255 

CH14  Load default 

settings 

no change 

This function resets all settings to the Factory 

setting. Check Factory setting table. 

Load Factory settings. X is row 

number factory setting table. 

 

Multiple connection

Daisychain connectivity

Installation depth

In centimeters

Swivel

Fixture is horizontally rotatable, 
indicated in degrees

Swivel

Fixture is vertically rotatable,
indicated in degrees

Installation size

In centimeters

Application area

Indoor or outdoor

Application area

Floor, wall or ceiling

Protection class

One, two or three

Cable length

Maximum cable attached
to the fixture in centimeters

Lifespan

Of the light source in hours

Driver

Inclusive or exclusive
Internal or external

Pressure

Maximum pressure on the 
fixture in kg/cm

2

Weight

In grams/kilograms

Curve

Minimal bending curve
in centimeters

LED pitch

Pitch between the LEDs 
in millimeters

Power supply

In VDC, VAC or milliAmpere

Power consumption

In VA or Watt

IP value

Ingress Protection classifies the 
degrees of protection provided against 
the intrusion of the product

Cutting length

Indicated by the cutting 
marks

LEDs

Kind of LED used in the 
fixture

Lenses

Availble lenses,
indicated in degrees

Plug & play

Easy connection using the 
SmartConnect system

White colour temperature

In different Kelvin values;
Cold white, neutral white, warm 
white or extra warm white

Colour

Available colours;
Amber, blue, red or green

Colour changing

RGB, RGB-W, RGB-A, 
AWB or Tunable White

DMX input

Fixture works on DMX512 
protocol

Magno dimming

Accurate dimming from
100 - 1% by using a magnet

Dynamic Control

Dynamic Power Control or
Dynamic Temperature Control

Combined product

Compose your own fixture

Warranty

3 or 5 years warranty on
the product

Energy label

Conformité Européenne

CE marking for free marketability
of industrial goods within the EU

r

h

ø

w

d

Dimmable

1-10 Volt, Phase, individual,
DMX dimmable or DALI

DRIVER

INCLUDED

DRIVER

EXTERNAL

Retail & Food LED modules

Clothing, furniture, kitchens, jewellery, 
shoes, bread, meat,
fish & vegetables & fruit.

Lightsource

Equipped with a CLS, Citizen or a Xicato 
LED module

Bluetooth controlled

By Casambi

CLS

DYNAMIC
COLOUR

COB

LIST OF SYMBOLS

Summary of Contents for REVO XXL DUO DMX Series

Page 1: ...nstalling or maintaining Don t install in a flammable or explosive area Warning Some surfaces can be hot Do not stare into the LED Don t modify or install genuine parts on this product Qualified technician Make sure all connectors are connected properly INDEX CONTENT SAFETY INFORMATION Floor Wall Ceiling 360º 360º 200 cm 3 6 kg 50 000 h 8º 12º 30º 61º 80º 12 x 46º 16 x Cree Luxeon IP67 100 240 VAC...

Page 2: ... lens kit superspot 8 8 lenses 110425 CLS REVO lens kit spot 12 8 lenses 110435 CLS REVO lens kit medium flood 30 8 lenses 110445 CLS REVO lens kit wide flood 61 8 lenses 110455 CLS REVO lens kit elliptical 12x46 8 lenses 871992 CLS mold set straight 8 26mm 871995 CLS mold set Paguro grey 122200 CLS D ta DMX adresser unit Y110795 G CLS REVO XL snoot grey Y110795 B CLS REVO XL snoot black Y110776 C...

Page 3: ... 3 times confirming storage Repeat these steps for the 3 other location marks 2018 CLS LED BV All rights reserved Information subject to change without notice CLS LED BV and all affiliated companies disclaim liability for injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this ...

Page 4: ... output off 2 255 intensity 2 255 CH11 Static output 2 0 no change 1 output off 2 255 intensity 2 255 CH12 Static output 3 0 no change 1 output off 2 255 intensity 2 255 CH13 Static output 4 0 no change 1 output off 2 255 intensity 2 255 CH14 Load default settings 0 no change This function resets all settings to the Factory setting Check Factory setting table X Load Factory settings X is row numbe...

Reviews: