background image

www.cls-led.com

www.cls-led.com

6

5

PROGRAMMING

FACTORY SETTING TABLE

All settings can be configured via DMX. Settings can be configured at once or separately. When one or a couple settings needs 
to be changed just leave all other setting values zero. This keeps those settings unchanged.Please check the table for more 
information.

Always use a DMX controller with digital interface. If not available, you can purchase the CLS D-ta DMX addresser unit (#122200).

First make sure to set the DATA on the DMX controller. To program the setting into the LED fixture follow the next steps. 

2

* If all LEDs flash 10 times, something went wrong. Please try again.  If the problem continues to occur, please contact your local sales distributor.

3

1

Place magnet

at one of the

indication marks.

All LEDs will

light up

After 2 seconds

all LED’s will flash

3 times

confirming

storage*

Repeat these

steps for the

3 other location

marks

2018 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim 
liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to 
use or reliance on the information contained in this manual. No part of this manual may be reproduced, in any form or by any means, 
without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of 
your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/General-Terms.pdf

2

4

2 x

1

2

3

4

5

6

2 x

Front plate

Glas

Lens holder

Front plate

Glas

Lens holder

1

3

6x

Secure in
       order

T20

T20

Make sure that
the items are clean 
and the rubber
sealing is correctly
in place!

LENS REPLACEMENT

LENS INDEX

1

5

2

3

4

Superspot 8º

Medium Flood 30º

Spot 12º

Flood 61º

Extra wide flood 80º

5

Elliptical 12x46º

Summary of Contents for REVO XXL DUO DMX Series

Page 1: ...nstalling or maintaining Don t install in a flammable or explosive area Warning Some surfaces can be hot Do not stare into the LED Don t modify or install genuine parts on this product Qualified technician Make sure all connectors are connected properly INDEX CONTENT SAFETY INFORMATION Floor Wall Ceiling 360º 360º 200 cm 3 6 kg 50 000 h 8º 12º 30º 61º 80º 12 x 46º 16 x Cree Luxeon IP67 100 240 VAC...

Page 2: ... lens kit superspot 8 8 lenses 110425 CLS REVO lens kit spot 12 8 lenses 110435 CLS REVO lens kit medium flood 30 8 lenses 110445 CLS REVO lens kit wide flood 61 8 lenses 110455 CLS REVO lens kit elliptical 12x46 8 lenses 871992 CLS mold set straight 8 26mm 871995 CLS mold set Paguro grey 122200 CLS D ta DMX adresser unit Y110795 G CLS REVO XL snoot grey Y110795 B CLS REVO XL snoot black Y110776 C...

Page 3: ... 3 times confirming storage Repeat these steps for the 3 other location marks 2018 CLS LED BV All rights reserved Information subject to change without notice CLS LED BV and all affiliated companies disclaim liability for injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this ...

Page 4: ... output off 2 255 intensity 2 255 CH11 Static output 2 0 no change 1 output off 2 255 intensity 2 255 CH12 Static output 3 0 no change 1 output off 2 255 intensity 2 255 CH13 Static output 4 0 no change 1 output off 2 255 intensity 2 255 CH14 Load default settings 0 no change This function resets all settings to the Factory setting Check Factory setting table X Load Factory settings X is row numbe...

Reviews: