background image

   

 

 

  

 

Version 1.5 

Summary of Contents for ArcPad 48 Integral (SmartWhite)

Page 1: ...Version 1 5...

Page 2: ...5 DMX 512 connection 10 3 6 Master slave connection 10 3 7 Stand alone operation 10 4 ArcPad 48 Integral SmartWhite DMX protocol 11 5 Control menu map 12 6 Fixture menu 14 6 1 Fixture Address 15 6 2 F...

Page 3: ...y Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part Do not overload wall outlets and extension cords as this can result in fire or electric shock...

Page 4: ...The fixture becomes very hot during operation Allow the fixture to cool approximately 30 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do n...

Page 5: ...egral can be arranged in any position orientation The ArcPpad 48 Integral s radiator with LEDs is mounted on an adjustable bracket for tilt adjustment into many positions Two slots 8 5mm wide in the f...

Page 6: ...ith all national and local electrical and construction codes and regulation The ArcPad 48 Integral is equiped with with a 5 cored power data cable The 3 cores serve for the power supply and next 2 shi...

Page 7: ...ArcPad 48 Integral SmartWhite 7...

Page 8: ...le 1 Disconnect the fixture from the mains 2 Put the top edge of the barn doors module into the second groove on the top side of the radiator detail A and the bottom edge into the second groove on the...

Page 9: ...al Interface or RDM Communicator user manuals to get more information about this products The way how to connect these interfaces to the DMX data link is figured below NOTE never connect the RDM commu...

Page 10: ...y fixture To set the program to be played see the Stand alone setting menu St AL Stand alone operation can be applied to the single fixture or to multiple fixtures operating synchronously Synchronous...

Page 11: ...uration 100 0 step proportional step proportional 3 0 31 32 63 64 95 96 127 128 143 144 159 160 191 192 223 224 255 Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Open...

Page 12: ...l 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 A001 dM Ad 001 512 MA SL d AbL MASt SLA InFo Poti FuLL totL rSEt EcO totL rSEt DM In Stro 0 255 F dim 0 255 tEMP Cur t Hi tE rSEt VErS IC1 PErS...

Page 13: ...Level 5 Menu Level 6 F dim 0 255 Stor dFSE MAn M PrE C WWhi Wh 01 Wh 03 dimr di 01 di 06 Man C WWhi 0 255 dimr 0 255 F dim 0 255 tESt St AL Auto Off tESt PrG 1 PrG 3 PLAY tESt PrG 1 PrG 3 Edit PrG 1...

Page 14: ...display with the four control buttons will appear on the screen of the RDM communicator The control buttons have the following functions ESCAPE button leaves menu without saving changes ENTER button...

Page 15: ...pear Now you can fullly control the fixture using the UP Down Enter Escape and Reset buttons 6 1 Fixture Address Use this menu to set the DMX address of the fixture or set the fixture as a Master Slav...

Page 16: ...m the choice Po ti Power On Time Use the menu item to read the number of operation hours for each LEDs operating mode FuLL Max light output from the fixture totL the function shows the total number of...

Page 17: ...to turn the display by 180 tEM U Temperature Unit Use this menu in order to display the fixture temperatures in desired units C or F LoAd Load of LEDs The menu allows to choose 2 different operating...

Page 18: ...ENTER button 5 Use the UP DOWN buttons to select desired program 6 Press the ENTER button to confirm the choice PLAY Playing program By enter to this menu a complete overview of all programs is offer...

Page 19: ...tory Users should not change the setting uPd M Updating mode The menu item allows you to update software in the fixture via either serial or USB port of PC The following are required in order to updat...

Page 20: ...tch this fixture to the update mode 1 Run the RDM Network and select menu item Remote LED Display 2 Use the UP DOWN buttons to find SPEC menu 3 Press the ENTER button 4 Use the UP DOWN buttons to sele...

Page 21: ...or use in DMX512 control systems it is the new open standard for DMX512 device configuration and status monitoring The RDM protocol allows data packets to be inserted into a DMX512 data stream without...

Page 22: ...versal Interface user manual for detail description of RDM operation 8 Error and information messages t M Er Temperature measuring error The message informs you that the LED module temperature sensor...

Page 23: ...s Full mode Eco mode 85 000 96 000 All LED channels Full mode Eco mode 85 000 96 000 L70 70 maintenance of initial lumen output in hours Electronics Control USITT DMX 512 RDM DMX protocol modes 4 2 3...

Page 24: ...ArcPad 48 Integral SmartWhite 24 Dimensions mm ArcPad 48 Integral Junction box Weight 3 kg...

Page 25: ...1 x Gasket of cable grommet M20 PF P N 1305 1388 Optional accessories 1 x Barn doors module in silver colour No 10980090 Eggcrate top hat module without lenses No 10980091 Flash cable RS232 DMX No 130...

Page 26: ...pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it There are no serviceable parts inside the device Maintenance and service operation...

Page 27: ...ArcPad 48 Integral SmartWhite 27...

Reviews: