background image

USER MANUAL : 

 

DOCUMENT NAME

 

ECO interface for connecting to GWF meters.

 

Large onboard non-volatile memory 

dependent). 

 

Logging  intervals  from  1  minute  to  1  month.  Information  is  internally  logged,  time  and  date  stamped  and 

transmitted at programmable intervals. 

 

Remote programming of all setup parameters via 

 

Ideal for leak detection, alarming to prevent water loss. 

 

Onboard Bluetooth can stream diagnostic information about signal strength, 

 

Touch sensitive button and LED's for manual wakeup to server and diagnostic purposes etc. 

 

1.3

 

Specifications 

 

 

NB-IoT LTE Cat NB1 communications

 

Supports B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B28/B66

 

Bluetooth interface 

 

Powered by battery or external 12V supply

 

Option of external power with battery failover and sleep

 

All management software supplied free

 

Standard Alkaline Batteries - 2 x D cells (5+ years)

 

2 x Pulse inputs 

 

ECO interface for connecting to GWF electronic meters

 

Up to 14400 record datalog memory (application 

 

Logging intervals 1 minute to 1 month

 

Rugged housing with seal eye 

 

Touch sensitive button and LED Diagnostics

 

Configuration and diagnostics through Bluetooth interface

 

Fully configurable remotely 

 

Stream data in real-time when powered by external

 

Size 185mm x 130mm x 55mm (including cable glands)

 

Housing Protection Class : IP68 - Max 1.2m, 30 days

 

Environment : -20°C to 80°C humidity = 90% non condensing. Check battery specifications for low power systems

 

Uses a Micro SIM card 

 
 

 

MANUAL : CDS543 NIMBUS PULSE LOGGER 

NAME 

CLASSIFICATION 

DATE 

PAGE

ECO interface for connecting to GWF meters..  

volatile memory - This logger can record in excess of 14400 datalog records

Logging  intervals  from  1  minute  to  1  month.  Information  is  internally  logged,  time  and  date  stamped  and 

vals.  

Remote programming of all setup parameters via NB-IoT link.  
Ideal for leak detection, alarming to prevent water loss.  
Onboard Bluetooth can stream diagnostic information about signal strength, network status etc. 

and LED's for manual wakeup to server and diagnostic purposes etc. 

IoT LTE Cat NB1 communications 

Supports B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B28/B66 

Powered by battery or external 12V supply 

external power with battery failover and sleep 

All management software supplied free 

x D cells (5+ years) 

ECO interface for connecting to GWF electronic meters 

record datalog memory (application dependent) 

Logging intervals 1 minute to 1 month 

Touch sensitive button and LED Diagnostics 
Configuration and diagnostics through Bluetooth interface 

time when powered by external supply 

Size 185mm x 130mm x 55mm (including cable glands) 

Max 1.2m, 30 days 

20°C to 80°C humidity = 90% non condensing. Check battery specifications for low power systems

 

PAGE 

records (application 

Logging  intervals  from  1  minute  to  1  month.  Information  is  internally  logged,  time  and  date  stamped  and 

etwork status etc.  

and LED's for manual wakeup to server and diagnostic purposes etc.  

20°C to 80°C humidity = 90% non condensing. Check battery specifications for low power systems 

Summary of Contents for CDS543

Page 1: ...ogger User Manual User 1 December 2020 V1 0 Draft Confidential CDS543 Nimbus Pulse Logger User Manual docx This document contains information relating to the rights of Cape Digital Solutions The confi...

Page 2: ...CUMENT NAME Issue Date V01 1 9 January 2021 MANUAL CDS543 NIMBUS PULSE LOGGER NAME CLASSIFICATION DATE PAGE AMENDMENT HISTORY Amendment Details Amended By Compile document Alex Romanov PAGE Amended By...

Page 3: ...ce 1 11 Sim card and battery installation 1 12 Installation considerations 2 Logger Setup 2 1 Setup via Bluetooth Configure 2 2 CDS543 Nimbus Pulse Logger Setup via Remote Configure 2 3 CDS543 Nimbus...

Page 4: ...of charge to allow clients to manage their own networks and data There are no monthly charges for collecting and hosting data as the client can provide this service themselves IoT technology NarrowBa...

Page 5: ...for low power systems Uses a Micro SIM card MANUAL CDS543 NIMBUS PULSE LOGGER NAME CLASSIFICATION DATE PAGE ECO interface for connecting to GWF meters volatile memory This logger can record in excess...

Page 6: ...two power configurations in this mode the logger can be continuously connected to the server allowing for the streaming Pulse logger uses standard D Cell alkaline batteries that will last several year...

Page 7: ...he lid luetooth is ready to receive an incoming connection Solid light indicates and active connection Logger is in Command Mode normally accompanied by an active Bluetooth connection Logger is curren...

Page 8: ...for 4 20mA isolated loop input 7 ECO Transmit line 8 ECO Receiveline 9 ECO ground connection 10 System earth used for transient voltage suppression MANUAL CDS543 NIMBUS PULSE LOGGER NAME CLASSIFICATIO...

Page 9: ...external 12V 8 15V 2A power supply or solar p Using a solar power source and also populating the logger with alkaline batteries means that the logger can be put into dual mode In this mode while there...

Page 10: ...on of water meter with electronic interface Please note the polarity of the interface Ground connection to pin 4 or 6 for Input 2 The onboard ECO interface is primarily used to support the GWF range o...

Page 11: ...cover the 5 Slide the cover plate forward again to lock into the base 1 2 MANUAL CDS543 NIMBUS PULSE LOGGER NAME CLASSIFICATION DATE PAGE installation oSIM and is installed as follows Slide the cover...

Page 12: ...ULSE LOGGER NAME CLASSIFICATION DATE PAGE Battery Installation Installation considerations logger is environmentally rated to IP68 max1 2m In order to achieve this it is ntering the logger are properl...

Page 13: ...AME CLASSIFICATION DATE PAGE configured using 3 different methods Through the local Bluetooth interface Remotely when a logger is powered and is currently online Via a scripting method for battery ope...

Page 14: ...rver which will search for the available remote devices in the immediate d a list of all the available devices will be displayed Should the device you are looking the Refresh button to start the searc...

Page 15: ...a connection immediately Once the Bluetooth connection has been established Cloudworks will automatically activate the correct configuration screen needed for each device type This device will immedia...

Page 16: ...block responses will be displayed in the Communications block This information can be cleared by right clicking in this box and before any of the settings changes or other instructions are accepted co...

Page 17: ...gger load Bluetooth communications active It would normally indicate lower than the recorded battery status in the datalog which is read while the e An indicator as to how this logger is being powered...

Page 18: ...e database during a reload device configuration event to a GSM network there are a couple of parameters that your GSM service provider will need from you in order to connect to their network These are...

Page 19: ...to be told that it is allowed to use data roaming For the datalogger setup the Wakeup Period refers to the time a logger remains asleep before waking and connecting to server to upload its data The Da...

Page 20: ...logger will abort the connection and go back to sleep battery or re This is for powered loggers only The server will continuously ping the logger at the interval set by this timer The logger will res...

Page 21: ...o to sleep rather than connect to the server When in Command Mode pressing this button will get the software to go and read all the configuration data from the logger and display it on the right hand...

Page 22: ...noperable and necessitate that it get sent back to the manufacturer for recovery Selecting Yes will start the upgrade process The diagnostic screen will display the progress of the upgrade the followi...

Page 23: ...k into Battery mode if battery logger MANUAL CDS543 NIMBUS PULSE LOGGER NAME CLASSIFICATION DATE PAGE ils to start try the following recovery Connect with the Bluetooth interface and switch the logger...

Page 24: ...tooth setup option Again d commands are sent to the device only after the parameter setup field has been left What this means is that while adjusting a parameter in its input box no commands are sent...

Page 25: ...MANUAL CDS543 NIMBUS PULSE LOGGER NAME CLASSIFICATION DATE PAGE establish Bear in mind if these parameters have changed the logger may re ine here preventing you from making any further changes If you...

Page 26: ...en you configure via the Bluetooth setup option with one or two minor All the parameter fields are empty at this point To create a script simply enter the new values for the parameters you wish The sc...

Page 27: ...e to each command for diagnostic purposes You can read back the current script to determine its status at any point by pressing the Read Script button Clear Script would delete the script from the dat...

Reviews: