14. FUNCTION TEST / DEMONSTRATION
NB:
Check the storage position of the
shower nozzle (which is flush with
the connecting head) and the
warm air nozzle (enclosed).
A function test is recommended after the toilet has been out of use for
some time, or after thorough cleaning. Switch the unit off at the main
switch, and on again after 30 seconds. This will trigger a short
initialisation programme, during which the WC must not be used.
Function test: raise seat and lid. Place test cover on bowl rim
(Photo X)
and lower seat again
(Photo Y).
Bypass detection device (weight on
bowl) by pressing all four push-buttons simultaneously for at least 2
seconds. This function will remain active for 5 minutes, whilst its
operating indicator – LED
(7.3)
- flashes red on the control panel
(7) (see
6 and 7).
Wait until you hear that the odour extraction process has
started. Then press and hold down the front left-hand push-button (main
push-button). The shower nozzle extends out and the system flushing
process runs before the actual spray follows. Release push-button after
a few seconds. The warm air nozzle extends and the warm air spray
begins. After about 20 seconds, the warm air function can be stopped
by pressing the front left-hand (main) push-button. Remove test cover.
Check the storage position of both nozzles. If the toilet’s functions are
to be demonstrated to someone (an interested visitor, for instance),
proceed as above under “function test”.