ZEFNET Pro User Manual
22
GROUNDING INSTRUCTIONS
This product must be grounded. If this product should malfunction,
grounding provides a path of least resistance for electric current to reduce
the risk of electric shock.
This hardwired EVSE is equipped with six service conductors, which are
terminated within the internal junction box. This product must be
connected to a grounded, metal, permanent wiring system, or an
equipment-grounding conductor must be run with the circuit conductors and
connected to the ground lead on the product.
In the case of having a Junction Box variant of the charger, ensure that the
grounding studs on both the top of the box and door are both grounded, as
indicated
WARNING
: Improper connection of the equipment grounding
conductor may result in a risk of electric shock. Check with a
qualified electrician if doubt exists as to whether the product is
properly grounded.