Models DC-1, -10, -20B DC Spark Testers
DC-1, -10, -20B Instruction Manual
–
Page 27
This configures which voltage to monitor when limiting the voltage.
use when the unit’s maximum voltage using VLIM as a starting point
to allow 2 decimal places. The setting of AUT will allow the
maximum the unit will produce.
“
AV
”:
Actual voltage as read from the high voltage power supply
“
EV
”:
Electrode voltage as read from the electrode
--
This configures the use of the discharge bar output. When enabled
the output will turn on when the voltage is set above 0.
When “Yes”, the
output will be used.
When “No”, the
output will remain inactive.
--
This delay used when voltage is called for till the voltage is output.
This is in seconds.
--
This configures the settings associated with fault detection for the unit.
--
FSMO TS0
This c
onfigures the unit’s fault sensitivity
mode. See Fault Sensitivity
in the “Definition of Terms” section of the manual for more
information. The values range from TS0 (normal sensitivity) to TS4
(maximum reduced sensitivity)
--
It is recommended that this be configured to the electrode length in
inches.
--
The Fault Pulse
“
FP
” time of the unit
may be set to Auto “AUT” or
set to a numeric value.
See Fault Pulse Length in the “Definition of
Terms” section of the manual for more information.
“AUT”
:
Auto mode uses default information to calculate a fault
pulse.
--