Start the machine
Do the following to start the machine:
1. On the PCU, press the START button (Figure 4-4).
2. Set the feed rate to zero (Figure 4-4).
3. Slowly open the PCU ball valve until the rotary speed reaches the desired
rate (Figure 4-4).
4. Engage the feed on the rotational drive unit (RDU) (Figure 4-5).
5. Slowly turn the feed rate screw to increase the feed rate until you reach the
desired feed rate. (Figure 4-4).
6. Adjust the feed rate and rotary speed as necessary to maintain the desired
cut.
7. Adjust the oil drip rate as needed. (Figure 4-4).
NOTICE
For best machine performance and service life, CLIMAX recommends
that the PCU oil drip rate not be adjusted below 6 drips per minute.
WARNING
Do not operate the machine if the bearing heats up significantly (that is,
more than approximately 15ºF (10ºC) above the ambient temperature).
Bearing heat may lead to thermal expansion and a loss of chucking
force, leading to a machine fall. Consult Section 5.5 on page 64 if the
bearing heats significantly.
Summary of Contents for FF1200
Page 2: ......
Page 4: ...Page B FF1200 FF2400 FF3600 Operating Manual CLIMAX GLOBAL LOCATIONS ...
Page 5: ...P N 95936 Rev 0 Page C CE DOCUMENTATION ...
Page 12: ...Page 4 FF1200 FF2400 FF3600 Operating Manual This page intentionally left blank ...
Page 14: ...Page 2 FF1200 FF2400 FF3600 Operating Manual This page intentionally left blank ...
Page 24: ...Labels Page 10 FF1200 FF2400 FF3600 Operating Manual This page left intentionally blank ...
Page 120: ...Page 106 FF1200 FF2400 FF3600 Operating Manual This page intentionally left blank ...
Page 122: ...Page 108 FF1200 FF2400 FF3600 Operating Manual This page intentionally left blank ...
Page 123: ...P N 95936 Rev 0 Page 109 APPENDIX C SDS Contact CLIMAX for the current safety data sheets ...
Page 124: ...Page 110 FF1200 FF2400 FF3600 Operating Manual This page intentionally left blank ...
Page 125: ......
Page 126: ......